Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
389
matching recommendationsSIC | 207 | Fats And Oils |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0301 # 07 Y:2002 | 07 | 2002 | ADJUST BURNERS FOR EFFICIENT OPERATION | $8,453 | $80 | Implemented |
IA0301 # 08 Y:2002 | 08 | 2002 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,523 | $1,465 | Implemented |
IA0301 # 09 Y:2002 | 09 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $118,409 | $74,000 | Implemented |
WI0424 # 01 Y:2002 | 01 | 2002 | USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL | $177,300 | $0 | Implemented |
WI0424 # 02 Y:2002 | 02 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,921 | $0 | Implemented |
WI0424 # 03 Y:2002 | 03 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,624 | $0 | Implemented |
WI0424 # 04 Y:2002 | 04 | 2002 | INSTALL OCCUPANCY SENSORS | $1,745 | $0 | Implemented |
UL0214 # 01 Y:1999 | 01 | 1999 | REPAIR OR REPLACE STEAM TRAPS | $12,122 | $6,950 | Implemented |
UL0214 # 02 Y:1999 | 02 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,243 | $119 | Implemented |
UL0214 # 03 Y:1999 | 03 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,476 | $2,192 | Not Implemented |
OK0556 # 06 Y:1998 | 06 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $633 | $1,020 | Implemented |
OK0556 # 03 Y:1998 | 03 | 1998 | REPAIR AND ELIMINATE STEAM LEAKS | $1,303 | $500 | Implemented |
OK0556 # 04 Y:1998 | 04 | 1998 | METER WASTE WATER | $119,889 | $0 | Not Implemented |
OK0556 # 05 Y:1998 | 05 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,048 | $3,000 | Not Implemented |
OK0556 # 07 Y:1998 | 07 | 1998 | INSTALL SOLID WASTE INCINERATOR FOR HEAT | $1,000 | $0 | Implemented |
OK0556 # 02 Y:1998 | 02 | 1998 | INSTALL / REPAIR INSULATION ON STEAM LINES | $227 | $678 | Implemented |
OK0556 # 01 Y:1998 | 01 | 1998 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $75,726 | $9,000 | Implemented |
UL0195 # 01 Y:1998 | 01 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,850 | $20 | Not Implemented |
UL0195 # 02 Y:1998 | 02 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,732 | $260 | Not Implemented |
UL0195 # 03 Y:1998 | 03 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $6,368 | $800 | Not Implemented |
UL0195 # 04 Y:1998 | 04 | 1998 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $2,628 | $0 | Implemented |
UL0195 # 05 Y:1998 | 05 | 1998 | UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS | $6,458,418 | $3,180,000 | Not Implemented |
UL0195 # 06 Y:1998 | 06 | 1998 | MINIMIZE WATER USAGE | $235,872 | $666,500 | Not Implemented |
UL0195 # 07 Y:1998 | 07 | 1998 | HIRE ADDITIONAL PERSONNEL TO REDUCE CHANGEOUT TIME | $70,000 | $0 | Implemented |
UL0195 # 08 Y:1998 | 08 | 1998 | CONDENSE OPERATION INTO ONE BUILDING | $105,000 | $300,000 | Implemented |