Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
18
matching recommendationsSIC | 2077 | Animal And Marine Fats And Oils |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0147 # 02 Y:1996 | 02 | 1996 | MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT | $35,224 | $55,000 | Implemented |
SD0147 # 10 Y:1996 | 10 | 1996 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $1,500 | $0 | Implemented |
SD0147 # 09 Y:1996 | 09 | 1996 | PURCHASE EQUIPMENT INSTEAD OF LEASING | $13,340 | $11,000 | Implemented |
SD0147 # 08 Y:1996 | 08 | 1996 | INSTALL OCCUPANCY SENSORS | $1,301 | $952 | Implemented |
SD0147 # 07 Y:1996 | 07 | 1996 | INSTALL SPECTRAL REFLECTORS / DELAMP | $4,917 | $4,005 | Implemented |
SD0147 # 06 Y:1996 | 06 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,547 | $2,779 | Implemented |
SD0147 # 05 Y:1996 | 05 | 1996 | REPAIR AND ELIMINATE STEAM LEAKS | $819 | $300 | Implemented |
SD0147 # 04 Y:1996 | 04 | 1996 | INSULATE BARE EQUIPMENT | $2,036 | $4,869 | Implemented |
SD0147 # 03 Y:1996 | 03 | 1996 | INSULATE BARE EQUIPMENT | $779 | $1,700 | Implemented |
SD0147 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,156 | $15,120 | Implemented |
SF0053 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,622 | $1,540 | Implemented |
SF0053 # 02 Y:1995 | 02 | 1995 | REPAIR AND ELIMINATE STEAM LEAKS | $384 | $150 | Implemented |
SF0053 # 03 Y:1995 | 03 | 1995 | INSTALL / REPAIR INSULATION ON STEAM LINES | $834 | $576 | Implemented |
SF0053 # 04 Y:1995 | 04 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,243 | $19,840 | Not Implemented |
SF0053 # 05 Y:1995 | 05 | 1995 | UPGRADE CONTROLS ON COMPRESSORS | $18,222 | $2,100 | Implemented |
SF0053 # 06 Y:1995 | 06 | 1995 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,019 | $28,800 | Not Implemented |
SF0053 # 07 Y:1995 | 07 | 1995 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $243,737 | $345,500 | Not Implemented |
SF0053 # 08 Y:1995 | 08 | 1995 | OPTIMIZE PLANT POWER FACTOR | $2,956 | $4,084 | Not Implemented |