Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,566
matching recommendationsSIC | 208 | Beverages |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0115 # 05 Y:2001 | 05 | 2001 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,057 | $1,225 | Implemented |
LE0115 # 07 Y:2001 | 07 | 2001 | INSULATE FEEDWATER TANK | $15,398 | $450 | Implemented |
LE0115 # 08 Y:2001 | 08 | 2001 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,792 | $768 | Implemented |
LE0114 # 04 Y:2001 | 04 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,376 | $0 | Implemented |
LE0114 # 06 Y:2001 | 06 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $8,207 | $2,500 | Implemented |
LE0114 # 07 Y:2001 | 07 | 2001 | TREAT AND REUSE RINSE WATERS | $753 | $3,750 | Implemented |
CO0483 # 01 Y:2001 | 01 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,160 | $0 | Implemented |
CO0483 # 03 Y:2001 | 03 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $90 | $0 | Implemented |
CO0483 # 04 Y:2001 | 04 | 2001 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $4,810 | $4,730 | Implemented |
ME0304 # 04 Y:2000 | 04 | 2000 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $1,848 | $0 | Implemented |
ME0304 # 05 Y:2000 | 05 | 2000 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $29,835 | $4,434 | Implemented |
OD0175 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $800 | $520 | Implemented |
WV0193 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $493 | $667 | Implemented |
WV0193 # 05 Y:2000 | 05 | 2000 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $373 | $190 | Implemented |
WV0193 # 10 Y:2000 | 10 | 2000 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $11,928 | $200 | Implemented |
WV0193 # 11 Y:2000 | 11 | 2000 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $540 | $80 | Implemented |
WV0193 # 12 Y:2000 | 12 | 2000 | METER WASTE WATER | $79,068 | $1,000 | Implemented |
WV0193 # 13 Y:2000 | 13 | 2000 | CLEAR AND RENT EXISTING SPACE | $3,100 | $2,000 | Implemented |
OR0364 # 01 Y:2000 | 01 | 2000 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $8,700 | $600 | Implemented |
SD0237 # 01 Y:2000 | 01 | 2000 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $28,985 | $88,000 | Implemented |
SD0237 # 02 Y:2000 | 02 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,408 | $2,800 | Implemented |
SD0237 # 03 Y:2000 | 03 | 2000 | REDUCE EXCESSIVE BOILER BLOWDOWN | $688 | $100 | Implemented |
SD0237 # 07 Y:2000 | 07 | 2000 | MINIMIZE WATER USAGE | $646 | $100 | Implemented |
SD0237 # 08 Y:2000 | 08 | 2000 | INSTALL AUTOMATIC PACKING EQUIPMENT | $40,972 | $7,200 | Implemented |
UL0233 # 01 Y:1999 | 01 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,210 | $50 | Implemented |