Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,299

matching recommendations
Reset
SIC 208 Beverages
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0220 # 07 Y:1987 07 1987 USE RADIANT HEATER FOR SPOT HEATING $976 $2,400 Not Implemented
OK0220 # 08 Y:1987 08 1987 INSTALL SET-BACK TIMERS $178 $0 Implemented
OK0220 # 09 Y:1987 09 1987 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $54 $62 Implemented
OK0220 # 10 Y:1987 10 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $71 $83 Implemented
CO0061 # 01 Y:1986 01 1986 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $5,180 $675 Implemented
CO0061 # 02 Y:1986 02 1986 INSTALL TIMERS AND/OR THERMOSTATS $2,701 $4,000 Implemented
CO0061 # 03 Y:1986 03 1986 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $673 $3,000 Implemented
CO0061 # 04 Y:1986 04 1986 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,929 $1,500 Not Implemented
CO0061 # 05 Y:1986 05 1986 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN $2,472 $800 Not Implemented
CO0061 # 06 Y:1986 06 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $129 $300 Not Implemented
CO0061 # 07 Y:1986 07 1986 INSTALL TURBULATORS $557 $1,000 Not Implemented
CO0061 # 08 Y:1986 08 1986 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $556 $900 Not Implemented
CO0061 # 09 Y:1986 09 1986 IMPROVE LUBRICATION PRACTICES $689 $0 Implemented
CO0061 # 10 Y:1986 10 1986 INSULATE BARE EQUIPMENT $695 $620 Implemented
CO0061 # 11 Y:1986 11 1986 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $160 $150 Implemented
CO0061 # 12 Y:1986 12 1986 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $419 $100 Not Implemented
CO0061 # 13 Y:1986 13 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $453 $217 Implemented
KU0180 # 01 Y:1985 01 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,925 $10,798 Not Implemented
KU0180 # 02 Y:1985 02 1985 INSTALL TIMERS AND/OR THERMOSTATS $3,940 $400 Implemented
KU0180 # 03 Y:1985 03 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,326 $0 Implemented
KU0180 # 04 Y:1985 04 1985 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $175 $128 Not Implemented
KU0180 # 05 Y:1985 05 1985 IMPROVE LUBRICATION PRACTICES $618 $1,155 Not Implemented
KU0180 # 06 Y:1985 06 1985 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $412 $50 Not Implemented
KU0180 # 07 Y:1985 07 1985 INSULATE BARE EQUIPMENT $265 $416 Not Implemented
KU0180 # 08 Y:1985 08 1985 INSULATE BARE EQUIPMENT $148 $220 Not Implemented