Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
63
matching recommendationsSIC | 208 | Beverages |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0342 # 11 Y:2006 | 11 | 2006 | INSULATE BARE EQUIPMENT | $18,125 | $2,570 | Implemented |
WV0342 # 01 Y:2006 | 01 | 2006 | REPAIR OR REPLACE STEAM TRAPS | $151,419 | $4,500 | Implemented |
WV0342 # 02 Y:2006 | 02 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $124,707 | $188,500 | Implemented |
WV0342 # 03 Y:2006 | 03 | 2006 | INCREASE AMOUNT OF CONDENSATE RETURNED | $103,142 | $100,000 | Implemented |
WV0342 # 04 Y:2006 | 04 | 2006 | REDUCE EXCESSIVE BOILER BLOWDOWN | $87,693 | $208,500 | Implemented |
WV0342 # 05 Y:2006 | 05 | 2006 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $76,391 | $42,250 | Implemented |
WV0342 # 06 Y:2006 | 06 | 2006 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $74,909 | $77,050 | Not Implemented |
WV0342 # 07 Y:2006 | 07 | 2006 | OPERATE BOILERS ON HIGH FIRE SETTING | $41,893 | $112,000 | Implemented |
WV0342 # 08 Y:2006 | 08 | 2006 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $26,961 | $1,000 | Implemented |
WV0342 # 09 Y:2006 | 09 | 2006 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $26,439 | $2,700 | Implemented |
WV0342 # 10 Y:2006 | 10 | 2006 | USE SYNTHETIC LUBRICANT | $23,049 | $280 | Implemented |
WV0342 # 14 Y:2006 | 14 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,759 | $35 | Implemented |
WV0342 # 15 Y:2006 | 15 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,938 | $0 | Not Implemented |
WV0342 # 16 Y:2006 | 16 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,240 | $93 | Not Implemented |
OD0175 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,794 | $49,324 | Not Implemented |
OD0175 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $800 | $520 | Implemented |
OD0107 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,066 | $7,697 | Implemented |
OD0107 # 02 Y:1998 | 02 | 1998 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $3,580 | $100 | Implemented |
OD0107 # 03 Y:1998 | 03 | 1998 | REPAIR OR REPLACE STEAM TRAPS | $280 | $780 | Implemented |
OD0102 # 05 Y:1998 | 05 | 1998 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $6,840 | $0 | n/a |
OD0102 # 04 Y:1998 | 04 | 1998 | CONVERT TO AQUEOUS CLEANING SYSTEM | $2,106 | $1,300 | n/a |
OD0102 # 03 Y:1998 | 03 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,629 | $509 | n/a |
OD0102 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,455 | $23,895 | n/a |
OD0102 # 01 Y:1998 | 01 | 1998 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $3,060 | $9,300 | n/a |
OD0088 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $359 | $672 | n/a |