Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

262

matching recommendations
Reset
SIC 208 Beverages
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0482 # 02 Y:2005 02 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,940 $500 Implemented
AM0482 # 03 Y:2005 03 2005 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $1,210 $0 Implemented
AM0482 # 04 Y:2005 04 2005 USE SYNTHETIC LUBRICANT $1,020 $0 Implemented
AM0482 # 05 Y:2005 05 2005 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $640 $0 Implemented
AM0482 # 06 Y:2005 06 2005 INSULATE BARE EQUIPMENT $280 $50 Not Implemented
AM0482 # 07 Y:2005 07 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $605 $350 Implemented
TP0004 # 01 Y:1999 01 1999 METER WASTE WATER $87,413 $6,200 n/a
TP0004 # 02 Y:1999 02 1999 MINIMIZE WATER USAGE $9,617 $655 n/a
TP0004 # 03 Y:1999 03 1999 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $4,724 $0 n/a
TP0004 # 04 Y:1999 04 1999 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,206 $12,268 n/a
TP0004 # 05 Y:1999 05 1999 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $2,165 $346 n/a
TP0004 # 06 Y:1999 06 1999 MINIMIZE WATER USAGE $1,664 $388 n/a
TP0004 # 07 Y:1999 07 1999 RECOVER AND REUSE COOLING WATER $1,313 $1,224 n/a
TP0004 # 08 Y:1999 08 1999 USE SYNTHETIC LUBRICANT $557 $0 n/a
AM0346 # 01 Y:1999 01 1999 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $18,650 $8,000 Implemented
AM0346 # 02 Y:1999 02 1999 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $5,300 $15,000 Implemented
AM0346 # 03 Y:1999 03 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $390 $200 Implemented
AM0346 # 04 Y:1999 04 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $410 $250 Implemented
AM0346 # 05 Y:1999 05 1999 INSULATE BARE EQUIPMENT $180 $35 Not Implemented
AM0346 # 06 Y:1999 06 1999 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $180 $140 Implemented
AM0314 # 01 Y:1998 01 1998 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $12,090 $0 Implemented
AM0314 # 02 Y:1998 02 1998 OPTIMIZE PLANT POWER FACTOR $10,380 $2,230 Implemented
AM0314 # 03 Y:1998 03 1998 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION $1,640 $0 Implemented
AM0314 # 04 Y:1998 04 1998 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,640 $220 Not Implemented
AM0314 # 05 Y:1998 05 1998 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,110 $330 Implemented