Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

43

matching recommendations
Reset
SIC 2082 Malt Beverages
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD1029 # 07 Y:2021 07 2021 USE MINIMUM STEAM OPERATING PRESSURE $1,533 $0 Not Implemented
UD1029 # 08 Y:2021 08 2021 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $995 $0 Not Implemented
UD1029 # 05 Y:2021 05 2021 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,922 $10,000 Not Implemented
UD1029 # 04 Y:2021 04 2021 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $138 $0 Not Implemented
UD1029 # 09 Y:2021 09 2021 TURN OFF STEAM TRACING DURING MILD WEATHER $876 $0 Not Implemented
UD1029 # 02 Y:2021 02 2021 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,027 $4,000 Not Implemented
UD1029 # 06 Y:2021 06 2021 REDUCE EXCESSIVE BOILER BLOWDOWN $2,088 $4,500 Not Implemented
UD1029 # 01 Y:2021 01 2021 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,908 $340 Not Implemented
UD1029 # 03 Y:2021 03 2021 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $541 $0 Not Implemented
UD0983 # 07 Y:2018 07 2018 INSTALL / REPAIR INSULATION ON STEAM LINES $819 $1,100 Implemented
UD0983 # 06 Y:2018 06 2018 USE OPTIMUM TEMPERATURE $836 $0 Not Implemented
UD0983 # 08 Y:2018 08 2018 USE OPTIMUM TEMPERATURE $355 $0 Implemented
UD0983 # 05 Y:2018 05 2018 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,115 $0 Implemented
UD0983 # 04 Y:2018 04 2018 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,393 $6,000 Not Implemented
UD0983 # 03 Y:2018 03 2018 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $1,019 $4,500 Not Implemented
UD0983 # 02 Y:2018 02 2018 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $13,719 $2,500 Not Implemented
UD0983 # 01 Y:2018 01 2018 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $390 $50 Not Implemented
UD0865 # 12 Y:2012 12 2012 UTILIZE A LESS EXPENSIVE COOLING METHOD $20,832 $25,000 Not Implemented
UD0865 # 11 Y:2012 11 2012 RECOVER WASTE HEAT FROM EQUIPMENT $42,877 $83,500 Not Implemented
UD0865 # 10 Y:2012 10 2012 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER $3,073 $9,219 Not Implemented
UD0865 # 09 Y:2012 09 2012 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $4,015 $9,000 Not Implemented
UD0865 # 07 Y:2012 07 2012 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $966 $1,600 Not Implemented
UD0865 # 04 Y:2012 04 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,395 $1,000 Not Implemented
UD0865 # 03 Y:2012 03 2012 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $30,494 $36,750 Not Implemented
UD0865 # 02 Y:2012 02 2012 INSTALL OCCUPANCY SENSORS $4,289 $1,200 Not Implemented