IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

43

matching recommendations
Reset
SIC 2082 Malt Beverages
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0865 # 07 Y:2012 07 2012 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $966 $1,600 Not Implemented
UD0865 # 08 Y:2012 08 2012 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,463 $0 Not Implemented
UD0865 # 09 Y:2012 09 2012 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $4,015 $9,000 Not Implemented
UD0865 # 10 Y:2012 10 2012 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER $3,073 $9,219 Not Implemented
UD0865 # 11 Y:2012 11 2012 RECOVER WASTE HEAT FROM EQUIPMENT $42,877 $83,500 Not Implemented
UD0865 # 12 Y:2012 12 2012 UTILIZE A LESS EXPENSIVE COOLING METHOD $20,832 $25,000 Not Implemented
UD0865 # 13 Y:2012 13 2012 UTILIZE A LESS EXPENSIVE COOLING METHOD $15,846 $24,600 Not Implemented
UM0183 # 04 Y:2001 04 2001 TREAT AND REUSE RINSE WATERS $780 $1,000 n/a
UM0183 # 05 Y:2001 05 2001 MINIMIZE WATER USAGE $2,400 $5,000 n/a
UM0183 # 08 Y:2001 08 2001 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $10,800 $14,400 n/a
UM0183 # 06 Y:2001 06 2001 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE $4,900 $7,400 n/a
UM0183 # 07 Y:2001 07 2001 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $2,500 $1,000 n/a
UM0183 # 03 Y:2001 03 2001 UTILIZE A LESS EXPENSIVE COOLING METHOD $700 $3,000 n/a
UM0183 # 02 Y:2001 02 2001 INSTALL OCCUPANCY SENSORS $1,400 $1,200 n/a
UM0183 # 01 Y:2001 01 2001 USE CORRECT SIZE STEAM TRAPS $2,880 $2,500 n/a
UD0089 # 03 Y:1983 03 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,029 $408 Not Implemented
UD0089 # 02 Y:1983 02 1983 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $12,879 $30,000 Implemented
UD0089 # 01 Y:1983 01 1983 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $5,685 $7,000 Not Implemented