Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
123
matching recommendationsSIC | 2086 | Bottled And Canned Soft Drinks |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0452 # 07 Y:2018 | 07 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,026 | $9,190 | Not Implemented |
LE0452 # 09 Y:2018 | 09 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,055 | $5,250 | Not Implemented |
LE0452 # 04 Y:2018 | 04 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,984 | $45,750 | Not Implemented |
LE0452 # 08 Y:2018 | 08 | 2018 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,475 | $30,000 | Not Implemented |
LE0452 # 01 Y:2018 | 01 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,430 | $1,000 | Not Implemented |
LE0452 # 02 Y:2018 | 02 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,260 | $600 | Not Implemented |
LE0452 # 05 Y:2018 | 05 | 2018 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $40,671 | $115,000 | Not Implemented |
LE0452 # 03 Y:2018 | 03 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,616 | $17,500 | Not Implemented |
DL0157 # 08 Y:2016 | 08 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $14,500 | $53,850 | Not Implemented |
DL0157 # 01 Y:2016 | 01 | 2016 | TURN OFF EQUIPMENT WHEN NOT IN USE | $11,140 | $0 | Implemented |
DL0157 # 02 Y:2016 | 02 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,860 | $2,250 | Not Implemented |
DL0157 # 03 Y:2016 | 03 | 2016 | TREAT AND REUSE RINSE WATERS | $34,545 | $41,405 | Implemented |
DL0157 # 04 Y:2016 | 04 | 2016 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $8,290 | $11,760 | Not Implemented |
DL0157 # 05 Y:2016 | 05 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $48,630 | $79,420 | Not Implemented |
DL0157 # 06 Y:2016 | 06 | 2016 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $14,700 | $44,740 | Implemented |
DL0157 # 07 Y:2016 | 07 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $22,170 | $77,500 | Implemented |
DL0157 # 09 Y:2016 | 09 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,440 | $46,960 | Implemented |
DL0055 # 12 Y:2010 | 12 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,467 | $6,000 | Implemented |
DL0055 # 09 Y:2010 | 09 | 2010 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $23,200 | $15,000 | Not Implemented |
DL0055 # 08 Y:2010 | 08 | 2010 | REDUCE VENTILATION AIR | $21,000 | $15,000 | Not Implemented |
DL0055 # 07 Y:2010 | 07 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,600 | $1,200 | Implemented |
DL0055 # 06 Y:2010 | 06 | 2010 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $9,000 | $3,000 | Implemented |
DL0055 # 05 Y:2010 | 05 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $82,808 | $125,000 | Implemented |
DL0055 # 04 Y:2010 | 04 | 2010 | REPLACE TREATED WATER WITH WELL / SURFACE WATER | $39,150 | $100,000 | Not Implemented |
DL0055 # 01 Y:2010 | 01 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $31,870 | $13,000 | Not Implemented |