Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
36
matching recommendationsSIC | 2086 | Bottled And Canned Soft Drinks |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0411 # 05 Y:2012 | 05 | 2012 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $15,341 | $5,000 | Not Implemented |
UM0411 # 04 Y:2012 | 04 | 2012 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $56,000 | $225,000 | Not Implemented |
UM0411 # 03 Y:2012 | 03 | 2012 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $821 | $100 | Implemented |
UM0411 # 02 Y:2012 | 02 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,402 | $200 | Not Implemented |
UM0411 # 01 Y:2012 | 01 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,396 | $2,000 | Not Implemented |
UM0370 # 07 Y:2010 | 07 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $33,206 | $1,000 | Implemented |
UM0370 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $76,860 | $90,000 | Implemented |
UM0370 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $17,172 | $8,188 | Implemented |
UM0370 # 03 Y:2010 | 03 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $11,691 | $7,980 | Not Implemented |
UM0370 # 04 Y:2010 | 04 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,537 | $200 | Not Implemented |
UM0370 # 05 Y:2010 | 05 | 2010 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $2,121 | $10 | Not Implemented |
UM0370 # 06 Y:2010 | 06 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,990 | $1,000 | Not Implemented |
UM0370 # 08 Y:2010 | 08 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $30,358 | $27,940 | Not Implemented |
UM0370 # 09 Y:2010 | 09 | 2010 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $19,669 | $15,750 | Not Implemented |
UM0370 # 10 Y:2010 | 10 | 2010 | INSTALL STORM WINDOWS AND DOORS | $1,156 | $9,300 | Implemented |
UM0321 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,338 | $0 | Implemented |
UM0321 # 07 Y:2007 | 07 | 2007 | INSTALL OCCUPANCY SENSORS | $1,558 | $5,130 | Implemented |
UM0321 # 06 Y:2007 | 06 | 2007 | TREAT AND REUSE RINSE WATERS | $3,084 | $8,021 | Not Implemented |
UM0321 # 04 Y:2007 | 04 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,307 | $1,000 | Implemented |
UM0321 # 03 Y:2007 | 03 | 2007 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $9,993 | $1,000 | Implemented |
UM0321 # 02 Y:2007 | 02 | 2007 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $11,520 | $21,700 | Not Implemented |
UM0321 # 01 Y:2007 | 01 | 2007 | USE HEAT PUMP FOR SPACE CONDITIONING | $33,455 | $21,730 | Not Implemented |
UM0319 # 05 Y:2007 | 05 | 2007 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $20,590 | $0 | Not Implemented |
UM0319 # 01 Y:2007 | 01 | 2007 | RECOVER AND REUSE COOLING WATER | $56,454 | $0 | Not Implemented |
UM0319 # 02 Y:2007 | 02 | 2007 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $31,763 | $0 | Not Implemented |