Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
33
matching recommendationsSIC | 2086 | Bottled And Canned Soft Drinks |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0805 # 15 Y:2009 | 15 | 2009 | OPTIMIZE PLANT POWER FACTOR | $1,903 | $5,000 | Not Implemented |
UD0805 # 11 Y:2009 | 11 | 2009 | INSULATE BARE EQUIPMENT | $3,797 | $4,283 | Implemented |
UD0805 # 10 Y:2009 | 10 | 2009 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,119 | $0 | Implemented |
UD0805 # 09 Y:2009 | 09 | 2009 | REDUCE EXCESSIVE BOILER BLOWDOWN | $5,312 | $5,000 | Implemented |
UD0805 # 08 Y:2009 | 08 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,938 | $6,703 | Implemented |
UD0805 # 07 Y:2009 | 07 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,327 | $8,043 | Implemented |
UD0805 # 06 Y:2009 | 06 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,710 | $16,000 | Not Implemented |
UD0805 # 05 Y:2009 | 05 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,974 | $2,000 | Not Implemented |
UD0805 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,872 | $25,117 | Implemented |
UD0805 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,619 | $17,147 | Implemented |
UD0805 # 02 Y:2009 | 02 | 2009 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $21,769 | $25,000 | Not Implemented |
UD0805 # 01 Y:2009 | 01 | 2009 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $39,022 | $12,000 | Not Implemented |
UD0805 # 18 Y:2009 | 18 | 2009 | ISOLATE HOT OR COLD EQUIPMENT | $666 | $0 | Implemented |
UD0805 # 17 Y:2009 | 17 | 2009 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $1,423 | $0 | Not Implemented |
UD0805 # 16 Y:2009 | 16 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,428 | $1,000 | Implemented |
UD0805 # 12 Y:2009 | 12 | 2009 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $3,741 | $0 | Not Implemented |
UD0805 # 13 Y:2009 | 13 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,689 | $0 | Implemented |
UD0805 # 14 Y:2009 | 14 | 2009 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,965 | $0 | Implemented |
UD0572 # 02 Y:1999 | 02 | 1999 | USE PLASTIC PALLETS INSTEAD OF WOOD | $38,960 | $110,457 | Implemented |
UD0572 # 03 Y:1999 | 03 | 1999 | UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS | $28,186 | $41,000 | Not Implemented |
UD0572 # 04 Y:1999 | 04 | 1999 | INSTALL SPECTRAL REFLECTORS / DELAMP | $9,457 | $-27,115 | Implemented |
UD0572 # 01 Y:1999 | 01 | 1999 | INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE | $948,600 | $580,553 | Not Implemented |
UD0167 # 06 Y:1985 | 06 | 1985 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $3,387 | $7,500 | Not Implemented |
UD0167 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,356 | $1,280 | Implemented |
UD0167 # 02 Y:1985 | 02 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,232 | $10,000 | Implemented |