Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

98

matching recommendations
Reset
SIC 2086 Bottled And Canned Soft Drinks
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MZ0056 # 01 Y:2010 01 2010 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $6,032 $1,160 Not Implemented
MZ0056 # 02 Y:2010 02 2010 INSTALL OCCUPANCY SENSORS $4,969 $950 Not Implemented
MZ0056 # 03 Y:2010 03 2010 TURN OFF EQUIPMENT WHEN NOT IN USE $2,784 $150 Not Implemented
MZ0056 # 04 Y:2010 04 2010 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,352 $150 Not Implemented
MZ0056 # 05 Y:2010 05 2010 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT $2,072 $1,000 Not Implemented
MZ0056 # 06 Y:2010 06 2010 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,900 $0 Not Implemented
MZ0056 # 07 Y:2010 07 2010 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $1,340 $800 Not Implemented
MZ0056 # 08 Y:2010 08 2010 RECOVER WASTE HEAT FROM EQUIPMENT $99,250 $80,000 Not Implemented
MZ0056 # 09 Y:2010 09 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,237 $1,300 Not Implemented
MZ0056 # 10 Y:2010 10 2010 REPAIR OR REPLACE STEAM TRAPS $113,700 $100,000 Not Implemented
NC0417 # 03 Y:2010 03 2010 RECOVER WASTE HEAT FROM EQUIPMENT $7,220 $2,500 Not Implemented
NC0417 # 05 Y:2010 05 2010 ADOPT IN-HOUSE MATERIAL GENERATION $26,671 $70,000 Not Implemented
NC0417 # 07 Y:2010 07 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $168 $199 Not Implemented
NC0417 # 08 Y:2010 08 2010 INSTALL OCCUPANCY SENSORS $2,865 $2,751 Not Implemented
NC0417 # 09 Y:2010 09 2010 USE PHOTOCELL CONTROLS $417 $122 Not Implemented
NC0417 # 06 Y:2010 06 2010 REPAIR OR REPLACE STEAM TRAPS $2,928 $1,000 Not Implemented
NC0417 # 04 Y:2010 04 2010 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $739 $180 Not Implemented
NC0417 # 02 Y:2010 02 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,199 $100 Implemented
NC0417 # 01 Y:2010 01 2010 RECOVER WASTE HEAT FROM EQUIPMENT $101,691 $362,675 Not Implemented
NC0413 # 01 Y:2010 01 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,881 $100 Implemented
NC0413 # 02 Y:2010 02 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,796 $50 Implemented
NC0413 # 04 Y:2010 04 2010 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,066 $1,000 Implemented
NC0413 # 05 Y:2010 05 2010 RECOVER WASTE HEAT FROM EQUIPMENT $67,233 $190,000 Not Implemented
NC0413 # 03 Y:2010 03 2010 INSULATE FEEDWATER TANK $283 $337 Implemented
MZ0053 # 03 Y:2010 03 2010 RECOVER WASTE HEAT FROM EQUIPMENT $22,455 $10,000 Implemented