IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

253

matching recommendations
Reset
SIC 2087 Flavoring Extracts And Syrups, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0180 # 02 Y:1985 02 1985 INSTALL TIMERS AND/OR THERMOSTATS $3,940 $400 Implemented
KU0180 # 03 Y:1985 03 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,326 $0 Implemented
KU0180 # 04 Y:1985 04 1985 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $175 $128 Not Implemented
KU0180 # 05 Y:1985 05 1985 IMPROVE LUBRICATION PRACTICES $618 $1,155 Not Implemented
KU0180 # 06 Y:1985 06 1985 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $412 $50 Not Implemented
KU0180 # 07 Y:1985 07 1985 INSULATE BARE EQUIPMENT $265 $416 Not Implemented
KU0180 # 08 Y:1985 08 1985 INSULATE BARE EQUIPMENT $148 $220 Not Implemented
KU0180 # 09 Y:1985 09 1985 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $206 $700 Implemented
KU0180 # 10 Y:1985 10 1985 ADD AIR SHIELDS TO TRUCKS TO INCREASE FUEL MILEAGE $127 $0 Not Implemented
KU0124 # 01 Y:1984 01 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,060 $1,800 Implemented
KU0124 # 02 Y:1984 02 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,287 $2,200 Implemented
KU0124 # 03 Y:1984 03 1984 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $698 $500 Not Implemented
KU0124 # 04 Y:1984 04 1984 REPAIR OR REPLACE STEAM TRAPS $2,492 $3,200 Implemented
KU0124 # 05 Y:1984 05 1984 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $392 $600 Implemented
KU0124 # 06 Y:1984 06 1984 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $361 $315 Implemented
KU0124 # 07 Y:1984 07 1984 INSULATE BARE EQUIPMENT $134 $300 Implemented
KU0124 # 08 Y:1984 08 1984 INSTALL / REPAIR INSULATION ON STEAM LINES $820 $1,200 Implemented
KU0124 # 09 Y:1984 09 1984 USE OPTIMUM TEMPERATURE $232 $450 Not Implemented
KU0124 # 10 Y:1984 10 1984 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $501 $323 Implemented
KU0124 # 11 Y:1984 11 1984 INSULATE BARE EQUIPMENT $542 $1,600 Implemented
KU0124 # 12 Y:1984 12 1984 INSTALL TIMERS AND/OR THERMOSTATS $1,644 $140 Not Implemented
KU0124 # 13 Y:1984 13 1984 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $2,322 $1,800 Implemented
KU0124 # 14 Y:1984 14 1984 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $1,965 $1,000 Not Implemented
KU0124 # 15 Y:1984 15 1984 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $886 $800 Implemented
KU0124 # 16 Y:1984 16 1984 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $732 $300 Implemented