Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
31
matching recommendationsSIC | 209 | Misc. Food And Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0519 # 07 Y:2002 | 07 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $286 | $742 | Implemented |
CO0519 # 06 Y:2002 | 06 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $103 | $280 | Implemented |
CO0519 # 05 Y:2002 | 05 | 2002 | INSTALL COMMON HEADER ON COMPRESSORS | $770 | $2,740 | Not Implemented |
CO0519 # 04 Y:2002 | 04 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,390 | $2,700 | Not Implemented |
CO0519 # 01 Y:2002 | 01 | 2002 | INSULATE BARE EQUIPMENT | $5,560 | $1,350 | Not Implemented |
CO0519 # 02 Y:2002 | 02 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,972 | $5,292 | Implemented |
CO0519 # 03 Y:2002 | 03 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $954 | $3,156 | Implemented |
SU0145 # 02 Y:2002 | 02 | 2002 | RECOVER AND REUSE COOLING WATER | $10,576 | $10,750 | Not Implemented |
SU0145 # 05 Y:2002 | 05 | 2002 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $280 | $25 | Implemented |
SU0145 # 01 Y:2002 | 01 | 2002 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $50,000 | $250,000 | Not Implemented |
SU0145 # 03 Y:2002 | 03 | 2002 | OPTIMIZE PLANT POWER FACTOR | $7,242 | $23,410 | Not Implemented |
SU0145 # 07 Y:2002 | 07 | 2002 | INSULATE BARE EQUIPMENT | $50 | $129 | Not Implemented |
SU0145 # 04 Y:2002 | 04 | 2002 | INSTALL OCCUPANCY SENSORS | $1,309 | $1,925 | Not Implemented |
SU0145 # 06 Y:2002 | 06 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $193 | $545 | Not Implemented |
OK0644 # 01 Y:2002 | 01 | 2002 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $190 | $280 | Not Implemented |
OK0644 # 02 Y:2002 | 02 | 2002 | INSTALL SPECTRAL REFLECTORS / DELAMP | $570 | $3 | Implemented |
OK0644 # 03 Y:2002 | 03 | 2002 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,441 | $1,738 | Implemented |
OK0644 # 04 Y:2002 | 04 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,779 | $5,835 | Not Implemented |
OK0644 # 05 Y:2002 | 05 | 2002 | INSTALL AUTOMATIC PACKING EQUIPMENT | $223,374 | $103,500 | Not Implemented |
OR0411 # 01 Y:2002 | 01 | 2002 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $20,500 | $66,000 | Not Implemented |
OR0411 # 02 Y:2002 | 02 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $8,050 | $25,951 | Implemented |
OR0411 # 03 Y:2002 | 03 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,510 | $4,500 | Implemented |
OR0411 # 04 Y:2002 | 04 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,377 | $6,300 | Implemented |
OR0411 # 05 Y:2002 | 05 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,746 | $0 | Implemented |
UU0019 # 05 Y:2002 | 05 | 2002 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $17,300 | $18,000 | Not Implemented |