Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
159
matching recommendationsSIC | 2091 | Canned And Cured Fish And Seafoods |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LS2319 # 05 Y:2023 | 05 | 2023 | USE OTHER WASTE CONCENTRATION METHODS | $34,000 | $200,000 | Not Implemented |
LS2319 # 04 Y:2023 | 04 | 2023 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $307 | $230 | Implemented |
LS2319 # 03 Y:2023 | 03 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,512 | $1,365 | Not Implemented |
LS2319 # 02 Y:2023 | 02 | 2023 | INSTALL TIMERS AND/OR THERMOSTATS | $291 | $50 | Not Implemented |
GT0899 # 01 Y:2017 | 01 | 2017 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $108,707 | $1,008 | Not Implemented |
GT0899 # 02 Y:2017 | 02 | 2017 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $7,187 | $1,000 | Implemented |
GT0899 # 03 Y:2017 | 03 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $29,097 | $4,967 | Implemented |
GT0899 # 04 Y:2017 | 04 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $40,882 | $10,400 | Not Implemented |
GT0899 # 05 Y:2017 | 05 | 2017 | INSTALL OCCUPANCY SENSORS | $8,883 | $9,708 | Implemented |
GT0899 # 06 Y:2017 | 06 | 2017 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $205,713 | $445,437 | Not Implemented |
DL0063 # 02 Y:2010 | 02 | 2010 | REDUCE VENTILATION AIR | $34,080 | $500 | Implemented |
DL0063 # 13 Y:2010 | 13 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,700 | $3,900 | Not Implemented |
DL0063 # 03 Y:2010 | 03 | 2010 | INCREASE AMOUNT OF CONDENSATE RETURNED | $31,600 | $1,610 | Implemented |
DL0063 # 04 Y:2010 | 04 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $33,400 | $57,000 | Not Implemented |
DL0063 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,900 | $166,850 | Implemented |
DL0063 # 06 Y:2010 | 06 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $22,000 | $3,000 | Implemented |
DL0063 # 07 Y:2010 | 07 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $18,958 | $60,000 | Not Implemented |
DL0063 # 08 Y:2010 | 08 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $12,220 | $100 | Not Implemented |
DL0063 # 09 Y:2010 | 09 | 2010 | REDUCE EXCESS STEAM BLEEDING | $14,034 | $419 | Implemented |
DL0063 # 11 Y:2010 | 11 | 2010 | INSTALL OCCUPANCY SENSORS | $12,978 | $1,012 | Implemented |
DL0063 # 12 Y:2010 | 12 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $11,600 | $1,585 | Implemented |
DL0063 # 18 Y:2010 | 18 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $733 | $615 | Implemented |
DL0063 # 01 Y:2010 | 01 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $35,600 | $100 | Implemented |
DL0063 # 17 Y:2010 | 17 | 2010 | INSULATE BARE EQUIPMENT | $3,993 | $30,400 | Not Implemented |