Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

159

matching recommendations
Reset
SIC 2091 Canned And Cured Fish And Seafoods
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LS2319 # 05 Y:2023 05 2023 USE OTHER WASTE CONCENTRATION METHODS $34,000 $200,000 Not Implemented
LS2319 # 04 Y:2023 04 2023 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $307 $230 Implemented
LS2319 # 03 Y:2023 03 2023 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,512 $1,365 Not Implemented
LS2319 # 02 Y:2023 02 2023 INSTALL TIMERS AND/OR THERMOSTATS $291 $50 Not Implemented
GT0899 # 01 Y:2017 01 2017 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $108,707 $1,008 Not Implemented
GT0899 # 02 Y:2017 02 2017 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $7,187 $1,000 Implemented
GT0899 # 03 Y:2017 03 2017 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $29,097 $4,967 Implemented
GT0899 # 04 Y:2017 04 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $40,882 $10,400 Not Implemented
GT0899 # 05 Y:2017 05 2017 INSTALL OCCUPANCY SENSORS $8,883 $9,708 Implemented
GT0899 # 06 Y:2017 06 2017 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $205,713 $445,437 Not Implemented
DL0063 # 02 Y:2010 02 2010 REDUCE VENTILATION AIR $34,080 $500 Implemented
DL0063 # 13 Y:2010 13 2010 RECOVER WASTE HEAT FROM EQUIPMENT $10,700 $3,900 Not Implemented
DL0063 # 03 Y:2010 03 2010 INCREASE AMOUNT OF CONDENSATE RETURNED $31,600 $1,610 Implemented
DL0063 # 04 Y:2010 04 2010 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $33,400 $57,000 Not Implemented
DL0063 # 05 Y:2010 05 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $31,900 $166,850 Implemented
DL0063 # 06 Y:2010 06 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $22,000 $3,000 Implemented
DL0063 # 07 Y:2010 07 2010 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $18,958 $60,000 Not Implemented
DL0063 # 08 Y:2010 08 2010 TURN OFF EQUIPMENT WHEN NOT IN USE $12,220 $100 Not Implemented
DL0063 # 09 Y:2010 09 2010 REDUCE EXCESS STEAM BLEEDING $14,034 $419 Implemented
DL0063 # 11 Y:2010 11 2010 INSTALL OCCUPANCY SENSORS $12,978 $1,012 Implemented
DL0063 # 12 Y:2010 12 2010 INSTALL / REPAIR INSULATION ON STEAM LINES $11,600 $1,585 Implemented
DL0063 # 18 Y:2010 18 2010 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $733 $615 Implemented
DL0063 # 01 Y:2010 01 2010 TURN OFF EQUIPMENT WHEN NOT IN USE $35,600 $100 Implemented
DL0063 # 17 Y:2010 17 2010 INSULATE BARE EQUIPMENT $3,993 $30,400 Not Implemented
DL0063 # 15 Y:2010 15 2010 CLOSE OFF UNNEEDED STEAM LINES $3,627 $400 Implemented