Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
487
matching recommendationsSIC | 2092 | Fresh Or Frozen Prepared Fish |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ORS003 # 07 Y:1999 | 07 | 1999 | MINIMIZE WATER USAGE | $-1,640 | $4,000 | Not Implemented |
ORS003 # 08 Y:1999 | 08 | 1999 | USE OTHER WASTE CONCENTRATION METHODS | $39,020 | $34,600 | Implemented |
ORS003 # 09 Y:1999 | 09 | 1999 | INSTALL EQUIPMENT TO MOVE PRODUCT | $80,220 | $15,400 | Implemented |
ORS002 # 01 Y:1999 | 01 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $13,472 | $27,939 | Implemented |
ORS002 # 02 Y:1999 | 02 | 1999 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,055 | $15,400 | Implemented |
ORS002 # 03 Y:1999 | 03 | 1999 | INSTALL / REPAIR INSULATION ON STEAM LINES | $880 | $700 | Implemented |
ORS002 # 04 Y:1999 | 04 | 1999 | REPLACE BOILER | $12,100 | $0 | Implemented |
ORS002 # 05 Y:1999 | 05 | 1999 | INSTALL AUTOMATIC PACKING EQUIPMENT | $166,000 | $121,000 | Implemented |
ORS002 # 06 Y:1999 | 06 | 1999 | INSTALL AUTOMATIC PACKING EQUIPMENT | $90,560 | $64,000 | Not Implemented |
ORS002 # 07 Y:1999 | 07 | 1999 | INSTALL AUTOMATIC PACKING EQUIPMENT | $67,400 | $200,000 | Not Implemented |
ORS002 # 08 Y:1999 | 08 | 1999 | REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING | $5,954 | $0 | Implemented |
OR0354 # 01 Y:1999 | 01 | 1999 | CLOSE OFF UNNEEDED STEAM LINES | $5,250 | $950 | Implemented |
OR0354 # 02 Y:1999 | 02 | 1999 | USE MINIMUM STEAM OPERATING PRESSURE | $560 | $0 | Not Implemented |
OR0354 # 03 Y:1999 | 03 | 1999 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $750 | $500 | Implemented |
OR0354 # 04 Y:1999 | 04 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $661 | $2,049 | Implemented |
OR0354 # 05 Y:1999 | 05 | 1999 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $950 | $0 | Not Implemented |
OR0351 # 01 Y:1999 | 01 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $25,756 | $0 | Not Implemented |
OR0351 # 02 Y:1999 | 02 | 1999 | AVOID FROST FORMATION ON EVAPORATORS | $31,270 | $48,000 | Not Implemented |
OR0351 # 03 Y:1999 | 03 | 1999 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $4,590 | $0 | Implemented |
OR0351 # 04 Y:1999 | 04 | 1999 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,270 | $3,100 | Not Implemented |
OR0351 # 05 Y:1999 | 05 | 1999 | OPTIMIZE PLANT POWER FACTOR | $1,595 | $9,600 | Not Implemented |
ME0253 # 01 Y:1998 | 01 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $30,662 | $83,099 | Implemented |
ME0253 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,977 | $26,897 | Implemented |
ME0253 # 03 Y:1998 | 03 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $12,878 | $10,000 | Implemented |
ME0253 # 04 Y:1998 | 04 | 1998 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $12,836 | $29,200 | Not Implemented |