Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
198
matching recommendationsSIC | 2095 | Roasted Coffee |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0493 # 05 Y:2005 | 05 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,400 | $2,500 | Not Implemented |
OR0493 # 06 Y:2005 | 06 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,500 | $0 | Not Implemented |
OR0493 # 07 Y:2005 | 07 | 2005 | INSTALL OCCUPANCY SENSORS | $2,400 | $3,600 | Not Implemented |
OR0493 # 08 Y:2005 | 08 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,900 | $17,000 | Not Implemented |
UF0362 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,108 | $706 | Not Implemented |
UF0362 # 02 Y:2005 | 02 | 2005 | INSTALL OCCUPANCY SENSORS | $5,310 | $2,525 | Not Implemented |
UF0362 # 03 Y:2005 | 03 | 2005 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $14,498 | $0 | Not Implemented |
UF0362 # 04 Y:2005 | 04 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $767 | $0 | Not Implemented |
UF0362 # 05 Y:2005 | 05 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $245 | $324 | Not Implemented |
UF0362 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,793 | $16,078 | Not Implemented |
UF0362 # 07 Y:2005 | 07 | 2005 | ADD AREA LIGHTING SWITCHES | $357 | $3,655 | Not Implemented |
UF0362 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $288 | $245 | Not Implemented |
UF0362 # 09 Y:2005 | 09 | 2005 | INSULATE BARE EQUIPMENT | $1,276 | $168 | Not Implemented |
UF0362 # 10 Y:2005 | 10 | 2005 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $8,012 | $0 | Not Implemented |
UF0362 # 11 Y:2005 | 11 | 2005 | RECYCLE FLUORESCENT LAMPS | $355 | $3,496 | Not Implemented |
LL0180 # 01 Y:2004 | 01 | 2004 | INSTALL OCCUPANCY SENSORS | $5,529 | $100 | Implemented |
LL0180 # 02 Y:2004 | 02 | 2004 | INSULATE BARE EQUIPMENT | $3,304 | $2,261 | Not Implemented |
LL0180 # 03 Y:2004 | 03 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,329 | $430 | Implemented |
LL0180 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,131 | $2,120 | Implemented |
LL0180 # 05 Y:2004 | 05 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,933 | $15 | Not Implemented |
LL0180 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,325 | $7,520 | Implemented |
LL0180 # 07 Y:2004 | 07 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,160 | $195 | Implemented |
LL0180 # 08 Y:2004 | 08 | 2004 | INSTALL OCCUPANCY SENSORS | $374 | $180 | Implemented |
LL0180 # 09 Y:2004 | 09 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $200 | $140 | Implemented |
KU0539 # 01 Y:2000 | 01 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $163,360 | $135,000 | Not Implemented |