Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
64
matching recommendationsSIC | 2097 | Manufactured Ice |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0367 # 02 Y:2005 | 02 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $200 | $0 | Not Implemented |
SD0327 # 02 Y:2003 | 02 | 2003 | USE COLD WASTE WATER TO COOL CHILLER FEED WATER | $15,838 | $12,500 | Not Implemented |
SD0327 # 01 Y:2003 | 01 | 2003 | UPGRADE OBSOLETE EQUIPMENT | $50,120 | $850,000 | Not Implemented |
SD0327 # 03 Y:2003 | 03 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,257 | $3,225 | Not Implemented |
SD0327 # 04 Y:2003 | 04 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $608 | $32 | Not Implemented |
SD0327 # 05 Y:2003 | 05 | 2003 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,124 | $5,000 | Not Implemented |
NC0223 # 06 Y:2001 | 06 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $10,524 | $40,000 | Not Implemented |
NC0223 # 05 Y:2001 | 05 | 2001 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $186 | $500 | Implemented |
NC0223 # 03 Y:2001 | 03 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $490 | $2,592 | Not Implemented |
NC0223 # 02 Y:2001 | 02 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $160 | $50 | Implemented |
NC0223 # 04 Y:2001 | 04 | 2001 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $3,729 | $10,000 | Not Implemented |
NC0223 # 01 Y:2001 | 01 | 2001 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $1,140 | $1,800 | Implemented |
UF0197 # 04 Y:1998 | 04 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,594 | $15,614 | Implemented |
UF0197 # 03 Y:1998 | 03 | 1998 | USE COLD WASTE WATER TO COOL CHILLER FEED WATER | $15,069 | $63,950 | Not Implemented |
UF0197 # 02 Y:1998 | 02 | 1998 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,334 | $1,200 | Implemented |
UF0197 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,885 | $3,682 | Not Implemented |
UF0197 # 05 Y:1998 | 05 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,990 | $1,150 | Implemented |
UF0197 # 06 Y:1998 | 06 | 1998 | UTILIZE OUTSIDE CONTRACTING | $108 | $0 | Not Implemented |
UF0197 # 07 Y:1998 | 07 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $5,315 | $7,000 | Not Implemented |
UF0197 # 08 Y:1998 | 08 | 1998 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $17,143 | $1,005 | Not Implemented |
UF0197 # 09 Y:1998 | 09 | 1998 | INSTALL AUTOMATIC PACKING EQUIPMENT | $64,930 | $280,000 | Not Implemented |
KG0097 # 05 Y:1997 | 05 | 1997 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $30,888 | $43,000 | n/a |
KG0097 # 04 Y:1997 | 04 | 1997 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $596,163 | $8,894 | n/a |
KG0097 # 03 Y:1997 | 03 | 1997 | IMPROVE PROCESS CONTROL TO PREVENT SPILLS OF MATERIAL | $90,970 | $800 | n/a |
KG0097 # 02 Y:1997 | 02 | 1997 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $8,416 | $8,894 | n/a |