Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
123
matching recommendationsSIC | 2098 | Macaroni And Spaghetti |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0180 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,240 | $5,343 | Not Implemented |
AS0180 # 06 Y:1996 | 06 | 1996 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $63,244 | $50,000 | Implemented |
AS0180 # 07 Y:1996 | 07 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,003 | $0 | Not Implemented |
AS0180 # 08 Y:1996 | 08 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $391 | $320 | Not Implemented |
AS0180 # 09 Y:1996 | 09 | 1996 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $1,648 | $30 | Implemented |
AS0180 # 10 Y:1996 | 10 | 1996 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $330 | $30 | Implemented |
AS0180 # 11 Y:1996 | 11 | 1996 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $1,041 | $1,780 | Implemented |
MO0162 # 01 Y:1995 | 01 | 1995 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,268 | $1,595 | Implemented |
MO0162 # 02 Y:1995 | 02 | 1995 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,585 | $200 | Implemented |
MO0162 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,761 | $2,978 | Implemented |
MO0162 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,142 | $8,220 | Implemented |
MO0162 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $158 | $0 | Implemented |
MO0162 # 06 Y:1995 | 06 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $16,300 | $33,261 | Implemented |
MO0162 # 07 Y:1995 | 07 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,699 | $225 | Implemented |
MO0162 # 08 Y:1995 | 08 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $8,282 | $5,203 | Implemented |
MO0162 # 09 Y:1995 | 09 | 1995 | USE SYNTHETIC LUBRICANT | $273 | $80 | Implemented |
MO0162 # 10 Y:1995 | 10 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $697 | $100 | Implemented |
MO0162 # 11 Y:1995 | 11 | 1995 | REDUCE SCRAP PRODUCTION | $4,050 | $300 | Implemented |
SF0070 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $602 | $610 | Implemented |
SF0070 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,041 | $9,983 | Not Implemented |
SF0070 # 03 Y:1995 | 03 | 1995 | INSTALL OCCUPANCY SENSORS | $2,395 | $4,330 | Not Implemented |
SF0070 # 04 Y:1995 | 04 | 1995 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $5,535 | $14,820 | Implemented |
SF0070 # 05 Y:1995 | 05 | 1995 | INSULATE BARE EQUIPMENT | $1,695 | $1,918 | Implemented |
SF0070 # 06 Y:1995 | 06 | 1995 | USE SYNTHETIC LUBRICANT | $421 | $758 | Implemented |
SF0070 # 07 Y:1995 | 07 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,114 | $40 | Implemented |