Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
113
matching recommendationsSIC | 2098 | Macaroni And Spaghetti |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0432 # 04 Y:1994 | 04 | 1994 | INSTALL OCCUPANCY SENSORS | $1,015 | $850 | Not Implemented |
KU0432 # 05 Y:1994 | 05 | 1994 | INCREASE USE OF AUTOMATION | $3,426 | $1,000 | Implemented |
KU0432 # 06 Y:1994 | 06 | 1994 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,605 | $0 | Implemented |
KU0432 # 07 Y:1994 | 07 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,141 | $250 | Not Implemented |
KU0432 # 08 Y:1994 | 08 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,770 | $11,382 | Implemented |
LT0144 # 01 Y:1989 | 01 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,927 | $0 | Implemented |
LT0144 # 02 Y:1989 | 02 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $34 | $17 | Implemented |
LT0144 # 03 Y:1989 | 03 | 1989 | INSTALL SET-BACK TIMERS | $1,494 | $0 | Implemented |
KU0265 # 01 Y:1988 | 01 | 1988 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $2,309 | $2,400 | Not Implemented |
KU0265 # 02 Y:1988 | 02 | 1988 | INSTALL SET-BACK TIMERS | $1,548 | $400 | Not Implemented |
KU0265 # 03 Y:1988 | 03 | 1988 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,892 | $5,000 | Implemented |
KU0265 # 04 Y:1988 | 04 | 1988 | INSTALL TURBULATORS | $2,263 | $1,250 | Implemented |
KU0265 # 05 Y:1988 | 05 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $771 | $0 | Implemented |
KU0265 # 06 Y:1988 | 06 | 1988 | RECOVER WASTE HEAT FROM EQUIPMENT | $606 | $700 | Implemented |
KU0265 # 07 Y:1988 | 07 | 1988 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $1,623 | $4,500 | Not Implemented |
KU0265 # 08 Y:1988 | 08 | 1988 | IMPROVE LUBRICATION PRACTICES | $4,120 | $0 | Implemented |
KU0265 # 09 Y:1988 | 09 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,325 | $0 | Implemented |
KU0265 # 10 Y:1988 | 10 | 1988 | MINIMIZE WATER USAGE | $9,368 | $6,400 | Implemented |
KU0265 # 11 Y:1988 | 11 | 1988 | RECOVER AND REUSE COOLING WATER | $7,327 | $6,400 | Implemented |
CO0084 # 01 Y:1987 | 01 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,130 | $300 | Not Implemented |
CO0084 # 02 Y:1987 | 02 | 1987 | INSTALL TURBULATORS | $1,404 | $600 | Not Implemented |
CO0084 # 03 Y:1987 | 03 | 1987 | INSTALL / REPAIR INSULATION ON STEAM LINES | $635 | $1,860 | Not Implemented |
CO0084 # 04 Y:1987 | 04 | 1987 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $283 | $1,200 | Not Implemented |
CO0084 # 05 Y:1987 | 05 | 1987 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $686 | $420 | Not Implemented |
CO0084 # 06 Y:1987 | 06 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $232 | $20 | Not Implemented |