Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
15
matching recommendationsSIC | 2099 | Food Preparations, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0505 # 01 Y:1996 | 01 | 1996 | OPTIMIZE PLANT POWER FACTOR | $12,351 | $9,000 | Implemented |
UD0505 # 02 Y:1996 | 02 | 1996 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $15,214 | $0 | Implemented |
UD0505 # 03 Y:1996 | 03 | 1996 | REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING | $8,648 | $4,000 | Implemented |
UD0505 # 04 Y:1996 | 04 | 1996 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,221 | $500 | Implemented |
UD0505 # 05 Y:1996 | 05 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,110 | $6,000 | Implemented |
UD0505 # 06 Y:1996 | 06 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,448 | $1,000 | Implemented |
UD0505 # 07 Y:1996 | 07 | 1996 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $1,640 | $0 | Implemented |
UD0284 # 01 Y:1989 | 01 | 1989 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $38,356 | $20,000 | Implemented |
UD0284 # 02 Y:1989 | 02 | 1989 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,285 | $0 | Implemented |
UD0284 # 04 Y:1989 | 04 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,210 | $0 | Implemented |
UD0284 # 05 Y:1989 | 05 | 1989 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,648 | $0 | Implemented |
UD0284 # 06 Y:1989 | 06 | 1989 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,404 | $2,300 | Implemented |
UD0166 # 01 Y:1985 | 01 | 1985 | RECOVER AND REUSE COOLING WATER | $10,849 | $7,160 | Implemented |
UD0166 # 02 Y:1985 | 02 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $28,600 | $40,000 | Implemented |
UD0166 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,258 | $50,000 | Implemented |