Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

63

matching recommendations
Reset
SIC 2099 Food Preparations, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0300 # 03 Y:1997 03 1997 USE LESS WASTEFUL PACKAGING $4,720 $0 Not Implemented
OR0300 # 01 Y:1997 01 1997 PURCHASE MATERIAL FROM SUPPLIER IN CUSTOMIZED PACKAGING $42,600 $0 Not Implemented
OR0300 # 04 Y:1997 04 1997 USE IN-PROCESS RECYCLING WHENEVER POSSIBLE $103 $0 Implemented
OR0300 # 02 Y:1997 02 1997 USE ONLY AMOUNT OF PACKAGING MATERIAL NECESSARY $400 $0 Implemented
OR0300 # 06 Y:1997 06 1997 INSTALL COMMON HEADER ON COMPRESSORS $1,105 $120 Implemented
OR0300 # 05 Y:1997 05 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,358 $0 Implemented
OR0300 # 07 Y:1997 07 1997 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $1,042 $1,000 Not Implemented
OR0300 # 08 Y:1997 08 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,025 $1,767 Implemented
OR0300 # 09 Y:1997 09 1997 OPTIMIZE PLANT POWER FACTOR $1,179 $2,200 Not Implemented
SF0122 # 03 Y:1997 03 1997 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $196 $811 Not Implemented
SF0122 # 09 Y:1997 09 1997 MOVE PRODUCT USING MECHANICAL MEANS $1,040 $1,000 Not Implemented
SF0122 # 04 Y:1997 04 1997 MINIMIZE WATER USAGE $1,544 $60 Not Implemented
SF0122 # 05 Y:1997 05 1997 RECOVER AND REUSE COOLING WATER $1,214 $765 Not Implemented
SF0122 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,448 $7,560 Not Implemented
SF0122 # 01 Y:1997 01 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $219 $376 Implemented
SF0122 # 06 Y:1997 06 1997 INSTALL REDUNDANT EQUIPMENT TO AVOID LOSSES CAUSED BY EQUIPMENT FAILURE AND ROUTINE MAINTENANCE $9,844 $900 Implemented
SF0122 # 07 Y:1997 07 1997 INCREASE USE OF AUTOMATION $43,680 $47,000 Not Implemented
SF0122 # 08 Y:1997 08 1997 INCREASE USE OF AUTOMATION $13,000 $6,000 Not Implemented
OK0528 # 01 Y:1997 01 1997 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $17,998 $48,754 Implemented
OK0528 # 02 Y:1997 02 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,011 $3,500 Implemented
OK0528 # 03 Y:1997 03 1997 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $3,099 $4,655 Not Implemented
OK0528 # 04 Y:1997 04 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $962 $114 Implemented
OK0528 # 05 Y:1997 05 1997 USE OPTIMUM THICKNESS INSULATION $747 $166 Implemented
OK0528 # 06 Y:1997 06 1997 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $6,149 $12,500 Not Implemented
OK0528 # 07 Y:1997 07 1997 MOVE PRODUCT USING MECHANICAL MEANS $39,936 $28,000 Not Implemented