Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,239
matching recommendationsSIC | 22 | Textile Mill Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
HO0053 # 04 Y:1993 | 04 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,255 | $2,804 | Implemented |
HO0053 # 05 Y:1993 | 05 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,072 | $1,000 | Implemented |
HO0053 # 06 Y:1993 | 06 | 1993 | INSTALL / REPAIR INSULATION ON STEAM LINES | $570 | $461 | Implemented |
HO0053 # 07 Y:1993 | 07 | 1993 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $168,361 | $700,000 | Not Implemented |
HO0053 # 08 Y:1993 | 08 | 1993 | OPTIMIZE PLANT POWER FACTOR | $8,740 | $6,990 | Not Implemented |
GT0498 # 01 Y:1993 | 01 | 1993 | DISCONNECT BALLASTS | $6,945 | $9,090 | Implemented |
GT0498 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,915 | $63,140 | Implemented |
GT0498 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $80 | $955 | Not Implemented |
GT0498 # 04 Y:1993 | 04 | 1993 | INSTALL OCCUPANCY SENSORS | $2,400 | $500 | Not Implemented |
GT0498 # 05 Y:1993 | 05 | 1993 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $73,000 | $116,200 | Implemented |
GT0498 # 06 Y:1993 | 06 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,655 | $37,220 | Implemented |
GT0498 # 07 Y:1993 | 07 | 1993 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $2,240 | $6,000 | Not Implemented |
GT0497 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,750 | $85,360 | Implemented |
GT0497 # 02 Y:1993 | 02 | 1993 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $7,440 | $6,000 | Not Implemented |
GT0497 # 03 Y:1993 | 03 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,025 | $2,000 | Not Implemented |
GT0497 # 04 Y:1993 | 04 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $16,170 | $60,500 | Implemented |
GT0497 # 05 Y:1993 | 05 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,745 | $0 | Not Implemented |
GT0497 # 06 Y:1993 | 06 | 1993 | OPERATE BOILERS ON HIGH FIRE SETTING | $1,035 | $0 | Implemented |
GT0497 # 07 Y:1993 | 07 | 1993 | MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT | $535 | $0 | Not Implemented |
GT0497 # 08 Y:1993 | 08 | 1993 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $26,415 | $24,720 | Implemented |
GT0492 # 01 Y:1993 | 01 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,090 | $450 | Implemented |
GT0492 # 02 Y:1993 | 02 | 1993 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,880 | $11,800 | Not Implemented |
GT0492 # 03 Y:1993 | 03 | 1993 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,620 | $7,280 | Not Implemented |
GT0492 # 04 Y:1993 | 04 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $26,920 | $103,820 | Implemented |
GT0492 # 05 Y:1993 | 05 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $12,320 | $0 | Implemented |