Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
43
matching recommendationsSIC | 22 | Textile Mill Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0224 # 05 Y:1991 | 05 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,079 | $16,200 | Implemented |
MA0224 # 04 Y:1991 | 04 | 1991 | REPAIR OR REPLACE STEAM TRAPS | $21,213 | $35,000 | Implemented |
MA0224 # 03 Y:1991 | 03 | 1991 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $25,667 | $19,927 | Not Implemented |
MA0224 # 02 Y:1991 | 02 | 1991 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $71,552 | $0 | Not Implemented |
MA0224 # 01 Y:1991 | 01 | 1991 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $46,881 | $0 | Not Implemented |
MA0224 # 08 Y:1991 | 08 | 1991 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,542 | $1,060 | Implemented |
MA0117 # 04 Y:1988 | 04 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $240 | $75 | Implemented |
MA0117 # 02 Y:1988 | 02 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $625 | $105 | Implemented |
MA0117 # 03 Y:1988 | 03 | 1988 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,384 | $5,878 | Not Implemented |
MA0117 # 05 Y:1988 | 05 | 1988 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $340 | $0 | Implemented |
MA0117 # 06 Y:1988 | 06 | 1988 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $11,656 | $2,040 | Not Implemented |
MA0032 # 07 Y:1985 | 07 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $485 | $120 | Implemented |
MA0032 # 06 Y:1985 | 06 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,902 | $2,400 | Implemented |
MA0032 # 05 Y:1985 | 05 | 1985 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $11,311 | $24,900 | Not Implemented |
MA0032 # 04 Y:1985 | 04 | 1985 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $173,755 | $126,200 | Not Implemented |
MA0032 # 03 Y:1985 | 03 | 1985 | BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT | $41,282 | $82,500 | Not Implemented |
MA0032 # 02 Y:1985 | 02 | 1985 | MODIFY DYE BECK | $4,749 | $1,800 | Not Implemented |
MA0032 # 01 Y:1985 | 01 | 1985 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $51,867 | $52,000 | Not Implemented |