Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

43

matching recommendations
Reset
SIC 22 Textile Mill Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0224 # 05 Y:1991 05 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,079 $16,200 Implemented
MA0224 # 04 Y:1991 04 1991 REPAIR OR REPLACE STEAM TRAPS $21,213 $35,000 Implemented
MA0224 # 03 Y:1991 03 1991 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $25,667 $19,927 Not Implemented
MA0224 # 02 Y:1991 02 1991 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $71,552 $0 Not Implemented
MA0224 # 01 Y:1991 01 1991 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $46,881 $0 Not Implemented
MA0224 # 08 Y:1991 08 1991 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,542 $1,060 Implemented
MA0117 # 04 Y:1988 04 1988 INSTALL TIMERS AND/OR THERMOSTATS $240 $75 Implemented
MA0117 # 02 Y:1988 02 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $625 $105 Implemented
MA0117 # 03 Y:1988 03 1988 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $2,384 $5,878 Not Implemented
MA0117 # 05 Y:1988 05 1988 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $340 $0 Implemented
MA0117 # 06 Y:1988 06 1988 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $11,656 $2,040 Not Implemented
MA0032 # 07 Y:1985 07 1985 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $485 $120 Implemented
MA0032 # 06 Y:1985 06 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,902 $2,400 Implemented
MA0032 # 05 Y:1985 05 1985 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $11,311 $24,900 Not Implemented
MA0032 # 04 Y:1985 04 1985 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $173,755 $126,200 Not Implemented
MA0032 # 03 Y:1985 03 1985 BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT $41,282 $82,500 Not Implemented
MA0032 # 02 Y:1985 02 1985 MODIFY DYE BECK $4,749 $1,800 Not Implemented
MA0032 # 01 Y:1985 01 1985 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $51,867 $52,000 Not Implemented