Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,239
matching recommendationsSIC | 22 | Textile Mill Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0547 # 07 Y:2015 | 07 | 2015 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $883 | $500 | Not Implemented |
NC0547 # 08 Y:2015 | 08 | 2015 | INSTALL OCCUPANCY SENSORS | $88 | $100 | Not Implemented |
NC0547 # 09 Y:2015 | 09 | 2015 | REDESIGN PROCESS | $461 | $2,000 | Not Implemented |
NC0547 # 10 Y:2015 | 10 | 2015 | DEVELOP A REPAIR/REPLACE POLICY | $2,028 | $4,256 | Implemented |
NC0547 # 11 Y:2015 | 11 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,688 | $281 | Implemented |
NC0547 # 12 Y:2015 | 12 | 2015 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $231 | $1,000 | Implemented |
NC0547 # 13 Y:2015 | 13 | 2015 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $675 | $200 | Implemented |
TT0156 # 01 Y:2015 | 01 | 2015 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $31,925 | $52,507 | Not Implemented |
TT0156 # 02 Y:2015 | 02 | 2015 | REPAIR AND ELIMINATE STEAM LEAKS | $13,551 | $15,000 | Not Implemented |
TT0156 # 03 Y:2015 | 03 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,241 | $10,000 | Not Implemented |
TT0156 # 04 Y:2015 | 04 | 2015 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $3,000 | $5,000 | Not Implemented |
TT0156 # 05 Y:2015 | 05 | 2015 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,769 | $1,651 | Implemented |
TT0156 # 06 Y:2015 | 06 | 2015 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,454 | $13 | Implemented |
NC0540 # 01 Y:2015 | 01 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,312 | $100 | Implemented |
NC0540 # 02 Y:2015 | 02 | 2015 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,496 | $659 | Implemented |
NC0540 # 03 Y:2015 | 03 | 2015 | REPAIR AND ELIMINATE STEAM LEAKS | $1,065 | $200 | Implemented |
NC0540 # 04 Y:2015 | 04 | 2015 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,539 | $1,500 | Not Implemented |
NC0540 # 05 Y:2015 | 05 | 2015 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $12,295 | $9,000 | Implemented |
NC0540 # 06 Y:2015 | 06 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,087 | $19,400 | Not Implemented |
NC0540 # 07 Y:2015 | 07 | 2015 | INSTALL OCCUPANCY SENSORS | $2,592 | $1,388 | Not Implemented |
NC0540 # 08 Y:2015 | 08 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $113 | $120 | Not Implemented |
NC0540 # 09 Y:2015 | 09 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $588 | $160 | Implemented |
NC0540 # 10 Y:2015 | 10 | 2015 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $6,804 | $22,500 | Implemented |
NC0540 # 11 Y:2015 | 11 | 2015 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $248 | $1,000 | Not Implemented |
NC0540 # 12 Y:2015 | 12 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,592 | $67,363 | Implemented |