IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

159

matching recommendations
Reset
SIC 22 Textile Mill Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0515 # 08 Y:1993 08 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $41,820 $80,090 Implemented
GT0515 # 07 Y:1993 07 1993 SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING $8,650 $6,560 Not Implemented
GT0515 # 05 Y:1993 05 1993 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $48,620 $100,640 Not Implemented
GT0515 # 03 Y:1993 03 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $680 $500 Implemented
GT0515 # 02 Y:1993 02 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,090 $0 Not Implemented
GT0515 # 01 Y:1993 01 1993 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $4,130 $9,570 Not Implemented
GT0515 # 06 Y:1993 06 1993 RECOVER WASTE HEAT FROM EQUIPMENT $45,330 $32,700 Not Implemented
GT0515 # 04 Y:1993 04 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,260 $14,500 Not Implemented
ME0115 # 05 Y:1993 05 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $965 $100 Implemented
ME0115 # 02 Y:1993 02 1993 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $106,916 $100,000 Not Implemented
ME0115 # 04 Y:1993 04 1993 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $1,080 $3,000 Not Implemented
ME0115 # 06 Y:1993 06 1993 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $25,600 $2,000 Implemented
ME0115 # 07 Y:1993 07 1993 PAY UTILITY BILLS ON TIME $3,042 $0 Not Implemented
ME0115 # 03 Y:1993 03 1993 OPTIMIZE PLANT POWER FACTOR $1,882 $2,500 Not Implemented
ME0115 # 01 Y:1993 01 1993 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,628 $800 Not Implemented
SD0068 # 07 Y:1993 07 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,576 $1,230 Implemented
SD0068 # 09 Y:1993 09 1993 INSTALL SET-BACK TIMERS $1,458 $2,000 Implemented
SD0068 # 10 Y:1993 10 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,598 $852 Implemented
SD0068 # 04 Y:1993 04 1993 INSTALL / REPAIR INSULATION ON STEAM LINES $149 $264 Implemented
SD0068 # 08 Y:1993 08 1993 INSTALL SPECTRAL REFLECTORS / DELAMP $1,560 $1,470 Implemented
SD0068 # 06 Y:1993 06 1993 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $58,730 $33,300 Not Implemented
SD0068 # 05 Y:1993 05 1993 REPAIR AND ELIMINATE STEAM LEAKS $6,065 $800 Implemented
SD0068 # 03 Y:1993 03 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,035 $140 Implemented
SD0068 # 01 Y:1993 01 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $731 $750 Implemented
SD0068 # 02 Y:1993 02 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $6,666 $17,938 Implemented