Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
118
matching recommendationsSIC | 22 | Textile Mill Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0177 # 03 Y:1999 | 03 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $8,265 | $420 | Not Implemented |
NC0177 # 02 Y:1999 | 02 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,366 | $2,141 | Implemented |
NC0177 # 01 Y:1999 | 01 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $434 | $120 | Implemented |
NC0177 # 04 Y:1999 | 04 | 1999 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $450 | $500 | Implemented |
NC0177 # 05 Y:1999 | 05 | 1999 | RECOVER AND REUSE COOLING WATER | $97,444 | $35,500 | Implemented |
NC0178 # 08 Y:1999 | 08 | 1999 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $20,173 | $2,500 | Implemented |
NC0178 # 07 Y:1999 | 07 | 1999 | MINIMIZE WATER USAGE | $74,238 | $5,000 | Implemented |
NC0178 # 05 Y:1999 | 05 | 1999 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $10,689 | $16,800 | Not Implemented |
NC0178 # 06 Y:1999 | 06 | 1999 | ADJUST BURNERS FOR EFFICIENT OPERATION | $6,258 | $800 | Not Implemented |
NC0178 # 01 Y:1999 | 01 | 1999 | MODIFY TEXTILE DRYERS | $72,691 | $1,000 | Implemented |
NC0178 # 02 Y:1999 | 02 | 1999 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $14,400 | $5,600 | Implemented |
NC0178 # 03 Y:1999 | 03 | 1999 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $15,967 | $6,000 | Not Implemented |
NC0178 # 04 Y:1999 | 04 | 1999 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $78,688 | $3,000 | Not Implemented |
NC0173 # 01 Y:1999 | 01 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $311 | $500 | Not Implemented |
NC0173 # 04 Y:1999 | 04 | 1999 | ADJUST BURNERS FOR EFFICIENT OPERATION | $1,211 | $800 | Not Implemented |
NC0173 # 07 Y:1999 | 07 | 1999 | ADD ADDITIONAL PRODUCTION SHIFT | $6,000 | $1,000 | Not Implemented |
NC0173 # 02 Y:1999 | 02 | 1999 | INSTALL OCCUPANCY SENSORS | $2,143 | $875 | Not Implemented |
NC0173 # 05 Y:1999 | 05 | 1999 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $235 | $0 | Not Implemented |
NC0173 # 06 Y:1999 | 06 | 1999 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $375 | $500 | Not Implemented |
NC0173 # 03 Y:1999 | 03 | 1999 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $7,486 | $27,000 | Not Implemented |
GT0671 # 04 Y:1999 | 04 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,420 | $600 | Not Implemented |
GT0671 # 05 Y:1999 | 05 | 1999 | REPAIR AND ELIMINATE STEAM LEAKS | $1,840 | $600 | Not Implemented |
GT0671 # 06 Y:1999 | 06 | 1999 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $900 | $1,040 | Not Implemented |
GT0671 # 07 Y:1999 | 07 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,872 | $20,086 | Not Implemented |
GT0671 # 08 Y:1999 | 08 | 1999 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $63,700 | $96,450 | Not Implemented |