Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
65
matching recommendationsSIC | 22 | Textile Mill Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0521 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,043 | $5,100 | Implemented |
NC0521 # 02 Y:2014 | 02 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $364,896 | $1,350,000 | Implemented |
NC0521 # 01 Y:2014 | 01 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $123,080 | $103,307 | Not Implemented |
NC0521 # 09 Y:2014 | 09 | 2014 | DEVELOP A REPAIR/REPLACE POLICY | $2,162 | $4,256 | Implemented |
NC0521 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,870 | $102,717 | Implemented |
NC0521 # 04 Y:2014 | 04 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $21,678 | $40,000 | Not Implemented |
NC0521 # 03 Y:2014 | 03 | 2014 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $57,030 | $40,000 | Implemented |
NC0521 # 05 Y:2014 | 05 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $41,376 | $72,000 | Not Implemented |
NC0521 # 08 Y:2014 | 08 | 2014 | INSTALL OCCUPANCY SENSORS | $2,313 | $650 | Implemented |
NC0513 # 11 Y:2014 | 11 | 2014 | KEEP BOILER TUBES CLEAN | $48,265 | $15,000 | Implemented |
NC0513 # 12 Y:2014 | 12 | 2014 | REPAIR OR REPLACE STEAM TRAPS | $40,007 | $6,200 | Implemented |
NC0513 # 18 Y:2014 | 18 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,375 | $37,264 | Not Implemented |
NC0513 # 02 Y:2014 | 02 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $89,082 | $860 | Implemented |
NC0513 # 17 Y:2014 | 17 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $20,435 | $19,607 | Not Implemented |
NC0513 # 16 Y:2014 | 16 | 2014 | INSULATE FEEDWATER TANK | $438 | $257 | Implemented |
NC0513 # 13 Y:2014 | 13 | 2014 | REPAIR AND ELIMINATE STEAM LEAKS | $20,840 | $20,000 | Implemented |
NC0513 # 14 Y:2014 | 14 | 2014 | INCREASE AMOUNT OF CONDENSATE RETURNED | $9,159 | $5,600 | Not Implemented |
NC0513 # 10 Y:2014 | 10 | 2014 | USE PHOTOCELL CONTROLS | $47 | $80 | Not Implemented |
NC0513 # 15 Y:2014 | 15 | 2014 | KEEP BOILER TUBES CLEAN | $13,546 | $500 | Not Implemented |
NC0513 # 08 Y:2014 | 08 | 2014 | INSTALL OCCUPANCY SENSORS | $3,462 | $3,470 | Implemented |
NC0513 # 01 Y:2014 | 01 | 2014 | DEVELOP A REPAIR/REPLACE POLICY | $137,290 | $454,945 | Implemented |
NC0513 # 07 Y:2014 | 07 | 2014 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,117 | $325 | Not Implemented |
NC0513 # 03 Y:2014 | 03 | 2014 | UPGRADE CONTROLS ON COMPRESSORS | $21,458 | $10,000 | Implemented |
NC0513 # 05 Y:2014 | 05 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $325 | $175 | Implemented |
NC0513 # 04 Y:2014 | 04 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,428 | $100 | Implemented |