Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
263
matching recommendationsSIC | 222 | Broadwoven Fabric Mills, Manmade |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0138 # 04 Y:1998 | 04 | 1998 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $1,267 | $0 | Implemented |
NC0138 # 03 Y:1998 | 03 | 1998 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $1,915 | $0 | Implemented |
NC0138 # 02 Y:1998 | 02 | 1998 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $16,312 | $0 | Not Implemented |
NC0138 # 01 Y:1998 | 01 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $525 | $1,431 | Not Implemented |
AM0319 # 01 Y:1998 | 01 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,640 | $450 | Not Implemented |
AM0319 # 02 Y:1998 | 02 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,645 | $900 | Not Implemented |
AM0319 # 03 Y:1998 | 03 | 1998 | ADD AREA LIGHTING SWITCHES | $5,110 | $1,700 | Not Implemented |
AM0319 # 04 Y:1998 | 04 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,400 | $30 | Not Implemented |
AM0319 # 05 Y:1998 | 05 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,960 | $490 | Not Implemented |
AM0319 # 06 Y:1998 | 06 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $445 | $405 | Not Implemented |
NC0155 # 07 Y:1998 | 07 | 1998 | CLEAR AND RENT EXISTING SPACE | $50,000 | $150,000 | Not Implemented |
NC0155 # 06 Y:1998 | 06 | 1998 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $15,130 | $9,000 | Not Implemented |
NC0155 # 05 Y:1998 | 05 | 1998 | AIR CONDITION ONLY SPACE NECESSARY | $3,045 | $5,426 | Not Implemented |
NC0155 # 04 Y:1998 | 04 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $386 | $0 | Not Implemented |
NC0155 # 03 Y:1998 | 03 | 1998 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $441 | $50 | Not Implemented |
NC0155 # 02 Y:1998 | 02 | 1998 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,802 | $700 | Not Implemented |
NC0155 # 01 Y:1998 | 01 | 1998 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $109 | $0 | Not Implemented |
MS0102 # 04 Y:1998 | 04 | 1998 | USE OPTIMUM TEMPERATURE | $17,981 | $0 | Implemented |
MS0102 # 07 Y:1998 | 07 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,227 | $8,447 | Not Implemented |
MS0102 # 06 Y:1998 | 06 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $7,306 | $47 | Implemented |
MS0102 # 05 Y:1998 | 05 | 1998 | TURN OFF STEAM TRACING DURING MILD WEATHER | $5,726 | $0 | Implemented |
MS0102 # 02 Y:1998 | 02 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $16,041 | $0 | Implemented |
MS0102 # 01 Y:1998 | 01 | 1998 | OPTIMIZE PLANT POWER FACTOR | $22,934 | $8,025 | Not Implemented |
MS0102 # 08 Y:1998 | 08 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $14,767 | $22,372 | Not Implemented |
MS0102 # 03 Y:1998 | 03 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,038 | $1,930 | Implemented |