Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center North Carolina State
Assessment Year 1998
Principal Product Contract woven fabrics
NAICS n/a
SIC 2221 - Broadwoven Fabric Mills, Manmade
Sales $5,000,000-$10,000,000
# of Employees 32
Plant Area (Sq.Ft.) 60,000
Annual Production 1,500 Thousand Feet
Production Hrs. Annual 4,000
Location (State) NC
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $73,215 2,185,522 kWh $0.03
Electricity Demand $36,685 5,605 kW-months/year $6.55
Electricity Fees $3,850 - $ -
Natural Gas $73,823 13,172 MMBtu $5.60
TOTAL ENERGY COSTS $187,573
RECOMMENDED SAVINGS* $22,701 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $3,182
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Water Disposal Solid Waste (non-haz) Personnel Changes Electricity Usage Electricity Demand Natural Gas Water Disposal Solid Waste (non-haz) Personnel Changes
$ kWh $ kW-months/year $ MMBtu $ Tgal $ lb $ $
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$525
Cost:
$1,431
$126 14,068 $399 42 - - - - - - - - $126
14,068
kWh
$399
42
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
lb
-
-
$
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$16,312
Cost:
-
- - $18,312 1,944 - - - - - - $(-2,000) - -
-
kWh
$18,312
1,944
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
lb
$(-2,000)
-
$
03: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT Savings:
$1,915
Cost:
-
$920 34,584 $995 106 - - - - - - - - $920
34,584
kWh
$995
106
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
lb
-
-
$
04: 2.7228 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM Savings:
$1,267
Cost:
-
$462 17,292 $805 62 - - - - - - - - $462
17,292
kWh
$805
62
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
lb
-
-
$
05: 3.4115 RECOVER AND REUSE COOLING WATER Savings:
$1,815
Cost:
$1,500
- - - - $1,401 250 $414 200,000 - - - - -
-
kWh
-
-
kW-months/year
$1,401
250
MMBtu
$414
200,000
Tgal
-
-
lb
-
-
$
06: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE Savings:
$113
Cost:
$200
- - - - - - - - $113 7,500 - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
$113
7,500
lb
-
-
$
07: 3.4153 USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER Savings:
$754
Cost:
$2,500
- - - - $582 104 $172 83,333 - - - - -
-
kWh
-
-
kW-months/year
$582
104
MMBtu
$172
83,333
Tgal
-
-
lb
-
-
$
TOTAL RECOMMENDED Savings:
$22,701
Cost:
$5,631
$1,508 65,944 $20,511 2,154 $1,983 354 $586 283,333 $113 7,500 $(-2,000) - $1,508
65,944
kWh
$20,511
2,154
kW-months/year
$1,983
354
MMBtu
$586
283,333
Tgal
$113
7,500
lb
$(-2,000)
-
$
TOTAL IMPLEMENTED Savings:
$3,182
Cost:
-
$1,382 51,876 $1,800 168 - - - - - - - - $1,382
51,876
kWh
$1,800
168
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
lb
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ Tgal $ lb $ $
Electricity Usage Electricity Demand Natural Gas Water Disposal Solid Waste (non-haz) Personnel Changes Electricity Usage Electricity Demand Natural Gas Water Disposal Solid Waste (non-haz) Personnel Changes