Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

237

matching recommendations
Reset
SIC 225 Knitting Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0505 # 02 Y:2014 02 2014 UTILIZE A LESS EXPENSIVE COOLING METHOD $14,010 $20,000 Not Implemented
NC0505 # 01 Y:2014 01 2014 MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT $1,293 $200 Implemented
NC0505 # 03 Y:2014 03 2014 RECOVER WASTE HEAT FROM EQUIPMENT $33,641 $67,830 Not Implemented
NC0505 # 05 Y:2014 05 2014 UPGRADE CONTROLS ON COMPRESSORS $1,108 $100 Implemented
NC0505 # 09 Y:2014 09 2014 DEVELOP A REPAIR/REPLACE POLICY $2,259 $4,256 Implemented
NC0505 # 08 Y:2014 08 2014 INSTALL OCCUPANCY SENSORS $2,395 $1,909 Not Implemented
NC0474 # 09 Y:2013 09 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,672 $100 Implemented
NC0474 # 08 Y:2013 08 2013 REPAIR OR REPLACE STEAM TRAPS $13,419 $5,700 Implemented
NC0474 # 07 Y:2013 07 2013 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $11,656 $25,000 Not Implemented
NC0474 # 01 Y:2013 01 2013 RECOVER WASTE HEAT FROM EQUIPMENT $93,874 $176,250 Implemented
NC0474 # 02 Y:2013 02 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $19,365 $52,188 Implemented
NC0474 # 03 Y:2013 03 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,078 $1,180 Implemented
NC0474 # 04 Y:2013 04 2013 USE PHOTOCELL CONTROLS $3,817 $7,000 Not Implemented
NC0474 # 05 Y:2013 05 2013 INSTALL OCCUPANCY SENSORS $1,019 $3,470 Implemented
NC0474 # 06 Y:2013 06 2013 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,431 $1,000 Implemented
NC0353 # 05 Y:2007 05 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $654 $100 Implemented
NC0353 # 02 Y:2007 02 2007 INSTALL / REPAIR INSULATION ON STEAM LINES $9,457 $1,526 Implemented
NC0353 # 04 Y:2007 04 2007 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,308 $2,000 Implemented
NC0353 # 01 Y:2007 01 2007 DEVELOP A REPAIR/REPLACE POLICY $17,011 $10,953 Implemented
NC0353 # 06 Y:2007 06 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,078 $20,770 Implemented
NC0353 # 07 Y:2007 07 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,055 $712 Implemented
NC0353 # 03 Y:2007 03 2007 REPAIR AND ELIMINATE STEAM LEAKS $3,562 $3,000 Implemented
NC0342 # 06 Y:2006 06 2006 ADJUST BURNERS FOR EFFICIENT OPERATION $4,323 $1,000 Implemented
NC0342 # 07 Y:2006 07 2006 INSULATE FEEDWATER TANK $676 $1,087 Not Implemented
NC0342 # 03 Y:2006 03 2006 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $592 $1,000 Implemented