Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
532
matching recommendationsSIC | 225 | Knitting Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0534 # 07 Y:2003 | 07 | 2003 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $6,624 | $21,000 | Not Implemented |
MA0534 # 08 Y:2003 | 08 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,663 | $9,742 | Not Implemented |
MA0534 # 09 Y:2003 | 09 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $470 | $1,416 | Not Implemented |
MS0217 # 01 Y:2002 | 01 | 2002 | INSTALL HEAT PIPES / RAISE COOLING SETPOINT | $236,267 | $271,000 | Not Implemented |
MS0217 # 02 Y:2002 | 02 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,022 | $38,355 | Not Implemented |
MS0217 # 03 Y:2002 | 03 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $12,081 | $35,838 | Not Implemented |
MS0217 # 04 Y:2002 | 04 | 2002 | INSTALL OCCUPANCY SENSORS | $5,071 | $799 | Not Implemented |
MS0217 # 05 Y:2002 | 05 | 2002 | INSTALL TIMERS AND/OR THERMOSTATS | $1,593 | $591 | Not Implemented |
MS0217 # 06 Y:2002 | 06 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,555 | $3,249 | Not Implemented |
MS0217 # 07 Y:2002 | 07 | 2002 | INSULATE BARE EQUIPMENT | $1,276 | $1,003 | Not Implemented |
MS0217 # 08 Y:2002 | 08 | 2002 | INSULATE BARE EQUIPMENT | $529 | $354 | Not Implemented |
MS0217 # 09 Y:2002 | 09 | 2002 | DISCONNECT BALLASTS | $431 | $510 | Not Implemented |
MS0217 # 10 Y:2002 | 10 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $249 | $155 | Not Implemented |
MS0217 # 11 Y:2002 | 11 | 2002 | REPAIR AND ELIMINATE STEAM LEAKS | $82 | $60 | Not Implemented |
NC0242 # 01 Y:2002 | 01 | 2002 | ADJUST BURNERS FOR EFFICIENT OPERATION | $10,271 | $1,000 | Implemented |
NC0242 # 02 Y:2002 | 02 | 2002 | FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM | $9,455 | $10,000 | Not Implemented |
NC0242 # 03 Y:2002 | 03 | 2002 | TREAT AND REUSE RINSE WATERS | $28,786 | $5,000 | Not Implemented |
NC0242 # 04 Y:2002 | 04 | 2002 | INSULATE BARE EQUIPMENT | $6,131 | $10,062 | Not Implemented |
NC0242 # 05 Y:2002 | 05 | 2002 | DEVELOP A REPAIR/REPLACE POLICY | $547 | $369 | Implemented |
NC0242 # 06 Y:2002 | 06 | 2002 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $2,368 | $1,200 | Implemented |
NC0242 # 07 Y:2002 | 07 | 2002 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $5,981 | $3,100 | Implemented |
WI0409 # 01 Y:2001 | 01 | 2001 | INSTALL SOLID WASTE INCINERATOR FOR HEAT | $34,371 | $130,000 | Not Implemented |
WI0409 # 02 Y:2001 | 02 | 2001 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $32,500 | $0 | Not Implemented |
WI0409 # 03 Y:2001 | 03 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,602 | $0 | Not Implemented |
WI0409 # 04 Y:2001 | 04 | 2001 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $5,314 | $4,600 | Not Implemented |