Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
80
matching recommendationsSIC | 2258 | Lace & Warp Knit Fabric Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0300 # 05 Y:2004 | 05 | 2004 | INSTALL OCCUPANCY SENSORS | $1,402 | $4,751 | Implemented |
NC0300 # 03 Y:2004 | 03 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,308 | $100 | Implemented |
NC0300 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,688 | $6,890 | Not Implemented |
NC0300 # 02 Y:2004 | 02 | 2004 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,558 | $5,000 | Implemented |
NC0300 # 01 Y:2004 | 01 | 2004 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,985 | $1,000 | Not Implemented |
NC0285 # 07 Y:2004 | 07 | 2004 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $11,507 | $23,675 | Not Implemented |
NC0285 # 04 Y:2004 | 04 | 2004 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $956 | $1,380 | Not Implemented |
NC0285 # 08 Y:2004 | 08 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,454 | $500 | Not Implemented |
NC0285 # 05 Y:2004 | 05 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $48,918 | $20,000 | Not Implemented |
NC0285 # 01 Y:2004 | 01 | 2004 | RECOVER AND REUSE COOLING WATER | $84,488 | $67,500 | Not Implemented |
NC0285 # 03 Y:2004 | 03 | 2004 | RECOVER AND REUSE COOLING WATER | $29,869 | $5,075 | Not Implemented |
NC0285 # 02 Y:2004 | 02 | 2004 | RECOVER AND REUSE COOLING WATER | $7,258 | $8,763 | Not Implemented |
NC0285 # 06 Y:2004 | 06 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $9,991 | $1,000 | Not Implemented |
MS0217 # 10 Y:2002 | 10 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $249 | $155 | Not Implemented |
MS0217 # 09 Y:2002 | 09 | 2002 | DISCONNECT BALLASTS | $431 | $510 | Not Implemented |
MS0217 # 11 Y:2002 | 11 | 2002 | REPAIR AND ELIMINATE STEAM LEAKS | $82 | $60 | Not Implemented |
MS0217 # 08 Y:2002 | 08 | 2002 | INSULATE BARE EQUIPMENT | $529 | $354 | Not Implemented |
MS0217 # 05 Y:2002 | 05 | 2002 | INSTALL TIMERS AND/OR THERMOSTATS | $1,593 | $591 | Not Implemented |
MS0217 # 07 Y:2002 | 07 | 2002 | INSULATE BARE EQUIPMENT | $1,276 | $1,003 | Not Implemented |
MS0217 # 01 Y:2002 | 01 | 2002 | INSTALL HEAT PIPES / RAISE COOLING SETPOINT | $236,267 | $271,000 | Not Implemented |
MS0217 # 06 Y:2002 | 06 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,555 | $3,249 | Not Implemented |
MS0217 # 03 Y:2002 | 03 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $12,081 | $35,838 | Not Implemented |
MS0217 # 04 Y:2002 | 04 | 2002 | INSTALL OCCUPANCY SENSORS | $5,071 | $799 | Not Implemented |
MS0217 # 02 Y:2002 | 02 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,022 | $38,355 | Not Implemented |
MA0487 # 02 Y:2001 | 02 | 2001 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $432,600 | $425,000 | Not Implemented |