Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
58
matching recommendationsSIC | 2269 | Finishing Plants, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KS2434 # 04 Y:2024 | 04 | 2024 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,537 | $6,440 | n/a |
KS2434 # 03 Y:2024 | 03 | 2024 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $1,889 | $6,569 | n/a |
KS2434 # 06 Y:2024 | 06 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $48,853 | $469,862 | n/a |
KS2434 # 05 Y:2024 | 05 | 2024 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $7,512 | $73,720 | n/a |
KS2434 # 01 Y:2024 | 01 | 2024 | REPAIR AND ELIMINATE STEAM LEAKS | $2,723 | $1,383 | n/a |
KS2434 # 02 Y:2024 | 02 | 2024 | INSTALL / REPAIR INSULATION ON STEAM LINES | $13,772 | $52,090 | n/a |
CC0026 # 01 Y:2023 | 01 | 2023 | INSULATE FEEDWATER TANK | $443 | $834 | n/a |
CC0026 # 02 Y:2023 | 02 | 2023 | INSTALL / REPAIR INSULATION ON STEAM LINES | $620 | $3,033 | n/a |
CC0026 # 03 Y:2023 | 03 | 2023 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $116,489 | $300,000 | n/a |
CC0026 # 04 Y:2023 | 04 | 2023 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $452 | $966 | n/a |
CC0026 # 05 Y:2023 | 05 | 2023 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $15,374 | $77,000 | n/a |
CC0026 # 06 Y:2023 | 06 | 2023 | REPAIR AND ELIMINATE STEAM LEAKS | $992 | $1,500 | n/a |
NC0225 # 06 Y:2001 | 06 | 2001 | KEEP BOILER TUBES CLEAN | $3,649 | $13,000 | Implemented |
NC0225 # 01 Y:2001 | 01 | 2001 | DEVELOP A REPAIR/REPLACE POLICY | $2,783 | $1,895 | Implemented |
NC0225 # 07 Y:2001 | 07 | 2001 | REPAIR AND ELIMINATE STEAM LEAKS | $8,655 | $3,500 | Implemented |
NC0225 # 08 Y:2001 | 08 | 2001 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $28,105 | $100,000 | Implemented |
NC0225 # 05 Y:2001 | 05 | 2001 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $20,000 | $40,000 | n/a |
NC0225 # 03 Y:2001 | 03 | 2001 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $27,745 | $33,990 | n/a |
NC0225 # 02 Y:2001 | 02 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,625 | $33,848 | Implemented |
NC0225 # 04 Y:2001 | 04 | 2001 | ELIMINATE COMBUSTIBLE GAS IN FLUE GAS | $15,365 | $5,000 | Implemented |
NC0204 # 02 Y:2000 | 02 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,133 | $257 | Implemented |
NC0204 # 07 Y:2000 | 07 | 2000 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $4,074 | $1,000 | Implemented |
NC0204 # 03 Y:2000 | 03 | 2000 | DISCONNECT BALLASTS | $2,900 | $6,800 | Implemented |
NC0204 # 04 Y:2000 | 04 | 2000 | AVOID REWINDING MOTORS MORE THAN TWICE | $1,634 | $1,282 | Not Implemented |
NC0204 # 05 Y:2000 | 05 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,960 | $730 | Implemented |