Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
649
matching recommendationsSIC | 228 | Yarn And Thread Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0870 # 02 Y:2009 | 02 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,570 | $1,000 | Not Implemented |
GT0870 # 01 Y:2009 | 01 | 2009 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $625 | $0 | Implemented |
GT0867 # 06 Y:2009 | 06 | 2009 | USE SYNTHETIC LUBRICANT | $1,440 | $0 | Implemented |
GT0867 # 05 Y:2009 | 05 | 2009 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $10,949 | $0 | Not Implemented |
GT0867 # 04 Y:2009 | 04 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,518 | $6,000 | Implemented |
GT0867 # 03 Y:2009 | 03 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,426 | $3,250 | Implemented |
GT0867 # 02 Y:2009 | 02 | 2009 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $8,794 | $4,000 | Implemented |
GT0867 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $52,318 | $89,971 | Not Implemented |
GT0844 # 14 Y:2007 | 14 | 2007 | INSTALL OCCUPANCY SENSORS | $1,245 | $560 | Not Implemented |
GT0844 # 13 Y:2007 | 13 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,869 | $5,000 | Not Implemented |
GT0844 # 12 Y:2007 | 12 | 2007 | INCREASE AMOUNT OF CONDENSATE RETURNED | $136,209 | $66,970 | Not Implemented |
GT0844 # 11 Y:2007 | 11 | 2007 | INCREASE AMOUNT OF CONDENSATE RETURNED | $26,394 | $20,000 | Not Implemented |
GT0844 # 10 Y:2007 | 10 | 2007 | INSULATE BARE EQUIPMENT | $10,329 | $19,630 | Not Implemented |
GT0844 # 09 Y:2007 | 09 | 2007 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $323,139 | $174,963 | Implemented |
GT0844 # 08 Y:2007 | 08 | 2007 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $65,444 | $81,971 | Not Implemented |
GT0844 # 07 Y:2007 | 07 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $12,291 | $28,172 | Not Implemented |
GT0844 # 06 Y:2007 | 06 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,808 | $5,132 | Not Implemented |
GT0844 # 05 Y:2007 | 05 | 2007 | USE SYNTHETIC LUBRICANT | $3,098 | $0 | Not Implemented |
GT0844 # 04 Y:2007 | 04 | 2007 | REDUCE EXCESSIVE BOILER BLOWDOWN | $44,955 | $10,000 | Not Implemented |
GT0844 # 03 Y:2007 | 03 | 2007 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $71,952 | $14,867 | Not Implemented |
GT0844 # 02 Y:2007 | 02 | 2007 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $35,650 | $40,000 | Not Implemented |
GT0844 # 01 Y:2007 | 01 | 2007 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $19,992 | $28,800 | Not Implemented |
NC0357 # 03 Y:2007 | 03 | 2007 | DEVELOP A REPAIR/REPLACE POLICY | $699 | $375 | Not Implemented |
NC0357 # 05 Y:2007 | 05 | 2007 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $277 | $100 | Implemented |
NC0357 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,527 | $4,761 | Not Implemented |