IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

38

matching recommendations
Reset
SIC 229 Miscellaneous Textile Goods
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CL1802 # 05 Y:2018 05 2018 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,710 $250 Not Implemented
CL1802 # 04 Y:2018 04 2018 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,272 $2,080 Not Implemented
CL1802 # 03 Y:2018 03 2018 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $6,049 $0 Not Implemented
CL1802 # 02 Y:2018 02 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,648 $20,897 Not Implemented
CL1802 # 01 Y:2018 01 2018 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $14,952 $0 Not Implemented
NC0282 # 02 Y:2004 02 2004 REDESIGN PROCESS $5,960 $6,000 n/a
NC0282 # 06 Y:2004 06 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,215 $936 n/a
NC0282 # 05 Y:2004 05 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,233 $240 n/a
NC0282 # 04 Y:2004 04 2004 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $3,574 $1,000 n/a
NC0282 # 03 Y:2004 03 2004 ADJUST BURNERS FOR EFFICIENT OPERATION $7,098 $1,000 n/a
NC0282 # 01 Y:2004 01 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $99,451 $151,800 n/a
TN0585 # 03 Y:1996 03 1996 INSTALL TIMERS AND/OR THERMOSTATS $1,905 $1,300 Implemented
TN0585 # 05 Y:1996 05 1996 USE SYNTHETIC LUBRICANT $486 $0 Implemented
TN0585 # 06 Y:1996 06 1996 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $308 $0 Not Implemented
TN0585 # 02 Y:1996 02 1996 INSTALL SPECTRAL REFLECTORS / DELAMP $5,531 $16,050 Not Implemented
TN0585 # 01 Y:1996 01 1996 MAKE A NEW BY-PRODUCT $31,813 $50,000 Implemented
TN0585 # 04 Y:1996 04 1996 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $1,575 $0 Not Implemented
TN0442 # 02 Y:1991 02 1991 INSTALL TIMERS AND/OR THERMOSTATS $4,589 $1,330 Implemented
TN0442 # 01 Y:1991 01 1991 ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE $5,281 $0 Implemented
TN0442 # 05 Y:1991 05 1991 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $12,142 $0 Implemented
TN0442 # 04 Y:1991 04 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,301 $600 Implemented
TN0442 # 03 Y:1991 03 1991 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $2,952 $0 Implemented
GT0423 # 03 Y:1990 03 1990 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $668 $500 Implemented
GT0423 # 02 Y:1990 02 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,135 $10,029 Implemented
GT0423 # 01 Y:1990 01 1990 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,280 $0 Not Implemented