Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

879

matching recommendations
Reset
SIC 229 Miscellaneous Textile Goods
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0742 # 03 Y:2015 03 2015 INSTALL / REPAIR INSULATION ON STEAM LINES $24,583 $5,560 Implemented
MA0742 # 04 Y:2015 04 2015 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $9,330 $1,000 Not Implemented
MA0742 # 05 Y:2015 05 2015 RECOVER WASTE HEAT FROM EQUIPMENT $8,116 $9,000 Implemented
MA0742 # 06 Y:2015 06 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $7,465 $11,685 Implemented
MA0742 # 07 Y:2015 07 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,112 $4,285 Not Implemented
MA0742 # 08 Y:2015 08 2015 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $4,024 $11,650 Implemented
NC0510 # 01 Y:2014 01 2014 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $55,430 $1,200 Implemented
NC0510 # 02 Y:2014 02 2014 INCREASE AMOUNT OF CONDENSATE RETURNED $5,472 $4,800 Not Implemented
NC0510 # 03 Y:2014 03 2014 INSTALL DE-AERATOR IN PLACE OF CONDENSATE TANK $1,500 $1,000 Implemented
NC0510 # 04 Y:2014 04 2014 RECOVER WASTE HEAT FROM EQUIPMENT $39,042 $3,000 Not Implemented
NC0510 # 05 Y:2014 05 2014 REPAIR OR REPLACE STEAM TRAPS $26,718 $67,500 Implemented
NC0510 # 06 Y:2014 06 2014 RECOVER WASTE HEAT FROM EQUIPMENT $9,896 $1,750 Not Implemented
NC0510 # 07 Y:2014 07 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,422 $100 Implemented
NC0510 # 08 Y:2014 08 2014 INSTALL OCCUPANCY SENSORS $1,444 $2,082 Implemented
NC0510 # 09 Y:2014 09 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $943 $1,993 Implemented
NC0510 # 10 Y:2014 10 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $811 $3,523 Implemented
NC0510 # 11 Y:2014 11 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $836 $240 Implemented
NC0510 # 12 Y:2014 12 2014 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $533 $286 Not Implemented
NC0510 # 13 Y:2014 13 2014 DEVELOP A REPAIR/REPLACE POLICY $2,594 $4,256 Not Implemented
NC0510 # 14 Y:2014 14 2014 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $2,665 $8,500 Not Implemented
DL0116 # 01 Y:2013 01 2013 RECOVER WASTE HEAT FROM EQUIPMENT $16,300 $10,000 Not Implemented
DL0116 # 02 Y:2013 02 2013 INSTALL TIMERS AND/OR THERMOSTATS $5,700 $20 Implemented
DL0116 # 03 Y:2013 03 2013 REDUCE VENTILATION AIR $2,320 $100 Not Implemented
DL0116 # 04 Y:2013 04 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $11,766 $11,200 Not Implemented
DL0116 # 05 Y:2013 05 2013 REDUCE VENTILATION AIR $11,206 $100 Not Implemented