Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
35
matching recommendationsSIC | 229 | Miscellaneous Textile Goods |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ME0200 # 02 Y:1996 | 02 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,060 | $2,200 | Not Implemented |
ME0200 # 03 Y:1996 | 03 | 1996 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $249 | $0 | Not Implemented |
ME0200 # 04 Y:1996 | 04 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,080 | $10,200 | Implemented |
ME0200 # 05 Y:1996 | 05 | 1996 | MINIMIZE WATER USAGE | $553 | $85 | Implemented |
ME0200 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,195 | $19,432 | Not Implemented |
NC0092 # 08 Y:1996 | 08 | 1996 | USE OPTIMUM THICKNESS INSULATION | $164 | $240 | Implemented |
NC0092 # 07 Y:1996 | 07 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $32,148 | $1,904 | Implemented |
NC0092 # 06 Y:1996 | 06 | 1996 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $5,891 | $50 | Implemented |
NC0092 # 05 Y:1996 | 05 | 1996 | DISCONNECT BALLASTS | $1,300 | $1,430 | Implemented |
NC0092 # 04 Y:1996 | 04 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $30,449 | $20,428 | Implemented |
NC0092 # 03 Y:1996 | 03 | 1996 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $27,124 | $60,000 | Implemented |
NC0092 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,972 | $708 | Implemented |
NC0092 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $314 | $1,400 | Implemented |
NC0092 # 09 Y:1996 | 09 | 1996 | USE DIRECT FLAME IMPINGEMENT OR INFRARED PROCESSING FOR CHAMBER TYPE HEATING | $100,360 | $600,000 | Not Implemented |
NC0092 # 10 Y:1996 | 10 | 1996 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $26,400 | $10,000 | Implemented |
NC0092 # 11 Y:1996 | 11 | 1996 | USE LESS WASTEFUL PACKAGING | $5,100 | $0 | Implemented |
TN0585 # 03 Y:1996 | 03 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $1,905 | $1,300 | Implemented |
TN0585 # 06 Y:1996 | 06 | 1996 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $308 | $0 | Not Implemented |
TN0585 # 01 Y:1996 | 01 | 1996 | MAKE A NEW BY-PRODUCT | $31,813 | $50,000 | Implemented |
TN0585 # 04 Y:1996 | 04 | 1996 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $1,575 | $0 | Not Implemented |
TN0585 # 05 Y:1996 | 05 | 1996 | USE SYNTHETIC LUBRICANT | $486 | $0 | Implemented |
TN0585 # 02 Y:1996 | 02 | 1996 | INSTALL SPECTRAL REFLECTORS / DELAMP | $5,531 | $16,050 | Not Implemented |
AS0168 # 08 Y:1996 | 08 | 1996 | REDUCE HEAT GAIN BY WINDOW TINTING | $2,966 | $10,750 | Not Implemented |
AS0168 # 07 Y:1996 | 07 | 1996 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $4,044 | $20,000 | Not Implemented |
AS0168 # 06 Y:1996 | 06 | 1996 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $11,824 | $0 | Implemented |