IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

99

matching recommendations
Reset
SIC 2298 Cordage And Twine
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0414 # 06 Y:1993 06 1993 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $329 $30 Implemented
KU0414 # 03 Y:1993 03 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,703 $520 Not Implemented
TN0499 # 09 Y:1993 09 1993 INSULATE BARE EQUIPMENT $443 $170 Implemented
TN0499 # 08 Y:1993 08 1993 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,297 $380 Not Implemented
TN0499 # 07 Y:1993 07 1993 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,740 $0 Not Implemented
TN0499 # 06 Y:1993 06 1993 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $2,725 $350 Not Implemented
TN0499 # 05 Y:1993 05 1993 INSULATE BARE EQUIPMENT $9,913 $30 Not Implemented
TN0499 # 03 Y:1993 03 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $16,068 $500 Implemented
TN0499 # 02 Y:1993 02 1993 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $26,982 $0 Implemented
TN0499 # 01 Y:1993 01 1993 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $40,654 $49 Implemented
TN0499 # 04 Y:1993 04 1993 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $14,164 $0 Not Implemented
OK0397 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,633 $3,692 Implemented
OK0397 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,271 $2,404 Implemented
OK0397 # 03 Y:1993 03 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $16,531 $11,150 Implemented
OK0397 # 04 Y:1993 04 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,448 $3,185 Implemented
OK0397 # 05 Y:1993 05 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $502 $768 Not Implemented
OK0397 # 06 Y:1993 06 1993 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $558 $0 Not Implemented
UD0109 # 05 Y:1983 05 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,827 $6,843 Implemented
UD0109 # 06 Y:1983 06 1983 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $15,968 $61,880 Not Implemented
UD0109 # 07 Y:1983 07 1983 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH $6,651 $5,475 Implemented
UD0109 # 04 Y:1983 04 1983 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $16,051 $40,000 Implemented
UD0109 # 03 Y:1983 03 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $12,630 $800 Implemented
UD0109 # 02 Y:1983 02 1983 INSULATE BARE EQUIPMENT $9,554 $600 Implemented
UD0109 # 01 Y:1983 01 1983 INSTALL / REPAIR INSULATION ON STEAM LINES $4,597 $980 Implemented