Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
355
matching recommendationsSIC | 2299 | Textile Goods, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CL1802 # 04 Y:2018 | 04 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,272 | $2,080 | Not Implemented |
CL1802 # 02 Y:2018 | 02 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,648 | $20,897 | Not Implemented |
CL1802 # 03 Y:2018 | 03 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,049 | $0 | Not Implemented |
GT0900 # 05 Y:2017 | 05 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $38,980 | $127,113 | Implemented |
GT0900 # 04 Y:2017 | 04 | 2017 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $42,468 | $8,000 | Not Implemented |
GT0900 # 01 Y:2017 | 01 | 2017 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,820 | $250 | Implemented |
GT0900 # 03 Y:2017 | 03 | 2017 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,890 | $180 | Implemented |
GT0900 # 02 Y:2017 | 02 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,671 | $250 | Implemented |
GT0900 # 06 Y:2017 | 06 | 2017 | INSULATE BARE EQUIPMENT | $16,527 | $106,785 | Not Implemented |
UA0157 # 01 Y:2016 | 01 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,132 | $35,339 | Not Implemented |
UA0157 # 02 Y:2016 | 02 | 2016 | INCREASE AMOUNT OF CONDENSATE RETURNED | $2,932 | $5,240 | Not Implemented |
UA0157 # 03 Y:2016 | 03 | 2016 | INSTALL / REPAIR INSULATION ON STEAM LINES | $320 | $215 | Not Implemented |
UA0157 # 04 Y:2016 | 04 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $658 | $100 | Not Implemented |
UA0157 # 05 Y:2016 | 05 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $430 | $1,520 | Implemented |
NC0510 # 01 Y:2014 | 01 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $55,430 | $1,200 | Implemented |
NC0510 # 03 Y:2014 | 03 | 2014 | INSTALL DE-AERATOR IN PLACE OF CONDENSATE TANK | $1,500 | $1,000 | Implemented |
NC0510 # 07 Y:2014 | 07 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,422 | $100 | Implemented |
NC0510 # 10 Y:2014 | 10 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $811 | $3,523 | Implemented |
NC0510 # 12 Y:2014 | 12 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $533 | $286 | Not Implemented |
NC0510 # 08 Y:2014 | 08 | 2014 | INSTALL OCCUPANCY SENSORS | $1,444 | $2,082 | Implemented |
NC0510 # 09 Y:2014 | 09 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $943 | $1,993 | Implemented |
NC0510 # 04 Y:2014 | 04 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $39,042 | $3,000 | Not Implemented |
NC0510 # 05 Y:2014 | 05 | 2014 | REPAIR OR REPLACE STEAM TRAPS | $26,718 | $67,500 | Implemented |
NC0510 # 11 Y:2014 | 11 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $836 | $240 | Implemented |
NC0510 # 06 Y:2014 | 06 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,896 | $1,750 | Not Implemented |