Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
63
matching recommendationsSIC | 2299 | Textile Goods, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0817 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,177 | $9,625 | Not Implemented |
GT0817 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40,933 | $164,201 | Not Implemented |
GT0817 # 01 Y:2006 | 01 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $8,981 | $1,333 | Implemented |
GT0804 # 03 Y:2005 | 03 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $15,926 | $12,224 | Implemented |
GT0804 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,303 | $1,600 | Implemented |
GT0804 # 05 Y:2005 | 05 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,432 | $2,500 | Implemented |
GT0804 # 04 Y:2005 | 04 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $49,306 | $75,000 | Not Implemented |
GT0804 # 02 Y:2005 | 02 | 2005 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $289 | $500 | Implemented |
GT0804 # 01 Y:2005 | 01 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,261 | $1,200 | Not Implemented |
GT0712 # 08 Y:2001 | 08 | 2001 | HEAT OIL TO PROPER TEMPERATURE FOR GOOD ATOMIZATION | $154,042 | $7,500 | n/a |
GT0712 # 07 Y:2001 | 07 | 2001 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $101,860 | $27,240 | n/a |
GT0712 # 06 Y:2001 | 06 | 2001 | INSULATE BARE EQUIPMENT | $152,112 | $51,570 | n/a |
GT0712 # 05 Y:2001 | 05 | 2001 | INSTALL SOLID WASTE INCINERATOR FOR HEAT | $1,166,246 | $1,875,000 | n/a |
GT0712 # 04 Y:2001 | 04 | 2001 | UPGRADE CONTROLS ON COMPRESSORS | $10,878 | $5,050 | n/a |
GT0712 # 03 Y:2001 | 03 | 2001 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $17,930 | $14,400 | n/a |
GT0712 # 02 Y:2001 | 02 | 2001 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $45,320 | $55,800 | n/a |
GT0712 # 01 Y:2001 | 01 | 2001 | USE MINIMUM STEAM OPERATING PRESSURE | $50,880 | $75,000 | n/a |
GT0451 # 04 Y:1991 | 04 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,910 | $4,750 | Implemented |
GT0451 # 01 Y:1991 | 01 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,391 | $0 | Implemented |
GT0451 # 02 Y:1991 | 02 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,600 | $34,240 | Implemented |
GT0451 # 03 Y:1991 | 03 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $868 | $3,917 | Implemented |
GT0451 # 05 Y:1991 | 05 | 1991 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,700 | $800 | Implemented |
GT0451 # 06 Y:1991 | 06 | 1991 | REDUCE FLUID FLOW RATES | $1,900 | $200 | Implemented |
GT0451 # 07 Y:1991 | 07 | 1991 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,300 | $1,200 | Implemented |
GT0451 # 08 Y:1991 | 08 | 1991 | IMPROVE LUBRICATION PRACTICES | $2,260 | $0 | Implemented |