Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
35
matching recommendationsSIC | 23 | Apparel And Other Textile Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MU0014 # 02 Y:2022 | 02 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $19,203 | $4,540 | Not Implemented |
MU0014 # 03 Y:2022 | 03 | 2022 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,023 | $0 | Implemented |
MU0014 # 04 Y:2022 | 04 | 2022 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $6,530 | $0 | Not Implemented |
MU0014 # 05 Y:2022 | 05 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,680 | $4,307 | Implemented |
MU0014 # 06 Y:2022 | 06 | 2022 | USE OPTIMUM TEMPERATURE | $1,469 | $155 | Not Implemented |
MU0014 # 07 Y:2022 | 07 | 2022 | TURN OFF EQUIPMENT WHEN NOT IN USE | $414 | $349 | Not Implemented |
MU0014 # 08 Y:2022 | 08 | 2022 | TURN OFF EQUIPMENT WHEN NOT IN USE | $109 | $0 | Implemented |
MU0014 # 09 Y:2022 | 09 | 2022 | RECOVER WASTE HEAT FROM EQUIPMENT | $91 | $261 | Not Implemented |
MU0014 # 01 Y:2022 | 01 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $32,107 | $30,064 | Not Implemented |
UM0342 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,736 | $13,776 | Not Implemented |
UM0342 # 07 Y:2008 | 07 | 2008 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $798 | $638 | Implemented |
UM0342 # 01 Y:2008 | 01 | 2008 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $9,661 | $7,350 | Not Implemented |
UM0342 # 05 Y:2008 | 05 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,462 | $515 | Not Implemented |
UM0342 # 06 Y:2008 | 06 | 2008 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,437 | $0 | Not Implemented |
UM0342 # 04 Y:2008 | 04 | 2008 | REDUCE VENTILATION AIR | $2,824 | $1,228 | Not Implemented |
UM0342 # 02 Y:2008 | 02 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,313 | $7,500 | Implemented |
UM0255 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,984 | $2,960 | Not Implemented |
UM0255 # 05 Y:2004 | 05 | 2004 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $2,917 | $8,000 | Not Implemented |
UM0255 # 01 Y:2004 | 01 | 2004 | INSULATE BARE EQUIPMENT | $10,323 | $6,486 | Implemented |
UM0255 # 02 Y:2004 | 02 | 2004 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $6,279 | $2,497 | Implemented |
UM0255 # 03 Y:2004 | 03 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,622 | $9,734 | Not Implemented |
UM0255 # 04 Y:2004 | 04 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,618 | $2,500 | Implemented |
UM0157 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,161 | $150 | Implemented |
UM0157 # 03 Y:2000 | 03 | 2000 | REDUCE EXCESSIVE BOILER BLOWDOWN | $1,224 | $4,430 | Implemented |
UM0157 # 04 Y:2000 | 04 | 2000 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $8,000 | $400 | Not Implemented |