Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,394
matching recommendationsSIC | 23 | Apparel And Other Textile Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MU0014 # 09 Y:2022 | 09 | 2022 | RECOVER WASTE HEAT FROM EQUIPMENT | $91 | $261 | Not Implemented |
MU0014 # 04 Y:2022 | 04 | 2022 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $6,530 | $0 | Not Implemented |
MU0014 # 02 Y:2022 | 02 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $19,203 | $4,540 | Not Implemented |
MU0014 # 07 Y:2022 | 07 | 2022 | TURN OFF EQUIPMENT WHEN NOT IN USE | $414 | $349 | Not Implemented |
MU0014 # 03 Y:2022 | 03 | 2022 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,023 | $0 | Implemented |
MU0014 # 01 Y:2022 | 01 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $32,107 | $30,064 | Not Implemented |
MU0014 # 05 Y:2022 | 05 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,680 | $4,307 | Implemented |
MU0014 # 08 Y:2022 | 08 | 2022 | TURN OFF EQUIPMENT WHEN NOT IN USE | $109 | $0 | Implemented |
CC0003 # 04 Y:2022 | 04 | 2022 | INSTALL TIMERS AND/OR THERMOSTATS | $5,980 | $0 | n/a |
CC0003 # 02 Y:2022 | 02 | 2022 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,633 | $0 | n/a |
CC0003 # 03 Y:2022 | 03 | 2022 | TURN OFF EQUIPMENT WHEN NOT IN USE | $990 | $0 | n/a |
CC0003 # 01 Y:2022 | 01 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,652 | $12,041 | n/a |
DL0199 # 04 Y:2021 | 04 | 2021 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $2,657 | $1,514 | Implemented |
DL0199 # 02 Y:2021 | 02 | 2021 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $1,784 | $0 | Implemented |
DL0199 # 06 Y:2021 | 06 | 2021 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $296 | $20 | Not Implemented |
DL0199 # 07 Y:2021 | 07 | 2021 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $280 | $1,170 | Not Implemented |
DL0199 # 13 Y:2021 | 13 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,579 | $2,106 | Implemented |
DL0199 # 08 Y:2021 | 08 | 2021 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $272 | $1,000 | Not Implemented |
DL0199 # 10 Y:2021 | 10 | 2021 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,675 | $7,837 | Not Implemented |
DL0199 # 12 Y:2021 | 12 | 2021 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $10,836 | $5,559 | Not Implemented |
DL0199 # 05 Y:2021 | 05 | 2021 | TURN OFF EQUIPMENT WHEN NOT IN USE | $341 | $805 | Not Implemented |
DL0199 # 11 Y:2021 | 11 | 2021 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $7,626 | $20,387 | Not Implemented |
DL0199 # 09 Y:2021 | 09 | 2021 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $988 | $3,000 | Not Implemented |
DL0199 # 03 Y:2021 | 03 | 2021 | REPAIR FAULTY LOUVERS AND DAMPERS | $2,440 | $2,275 | Not Implemented |
DL0199 # 01 Y:2021 | 01 | 2021 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,226 | $0 | Implemented |