Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,394
matching recommendationsSIC | 23 | Apparel And Other Textile Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0126 # 05 Y:1984 | 05 | 1984 | INSTALL TURBULATORS | $162 | $441 | Not Implemented |
KU0126 # 06 Y:1984 | 06 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $369 | $0 | Implemented |
KU0126 # 07 Y:1984 | 07 | 1984 | INSULATE BARE EQUIPMENT | $200 | $216 | Not Implemented |
KU0126 # 08 Y:1984 | 08 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $184 | $140 | Implemented |
KU0126 # 09 Y:1984 | 09 | 1984 | REPAIR AND ELIMINATE STEAM LEAKS | $196 | $150 | Implemented |
KU0126 # 10 Y:1984 | 10 | 1984 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $58 | $220 | Not Implemented |
KU0126 # 11 Y:1984 | 11 | 1984 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $59 | $40 | Implemented |
KU0126 # 12 Y:1984 | 12 | 1984 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $106 | $165 | Not Implemented |
KU0122 # 01 Y:1984 | 01 | 1984 | REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS | $9,129 | $5,400 | Not Implemented |
KU0122 # 02 Y:1984 | 02 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,060 | $5,000 | Implemented |
KU0122 # 03 Y:1984 | 03 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,649 | $3,690 | Implemented |
KU0122 # 04 Y:1984 | 04 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $3,254 | $450 | Implemented |
KU0122 # 05 Y:1984 | 05 | 1984 | KEEP BOILER TUBES CLEAN | $1,926 | $2,000 | Implemented |
KU0122 # 06 Y:1984 | 06 | 1984 | INSTALL TURBULATORS | $1,610 | $2,120 | Not Implemented |
KU0122 # 07 Y:1984 | 07 | 1984 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,439 | $1,985 | Implemented |
KU0122 # 08 Y:1984 | 08 | 1984 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $423 | $0 | Implemented |
KU0122 # 09 Y:1984 | 09 | 1984 | INSTALL SET-BACK TIMERS | $401 | $50 | Implemented |
KU0122 # 10 Y:1984 | 10 | 1984 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $272 | $280 | Implemented |
KU0122 # 11 Y:1984 | 11 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $211 | $300 | Implemented |
KU0122 # 12 Y:1984 | 12 | 1984 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $169 | $0 | Implemented |
TN0201 # 01 Y:1984 | 01 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,160 | $10 | Implemented |
TN0201 # 02 Y:1984 | 02 | 1984 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,336 | $2,325 | Implemented |
TN0201 # 03 Y:1984 | 03 | 1984 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $610 | $2,500 | Not Implemented |
TN0201 # 04 Y:1984 | 04 | 1984 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $94 | $45 | Implemented |
KU0116 # 01 Y:1984 | 01 | 1984 | INSTALL SOLID WASTE INCINERATOR FOR HEAT | $22,384 | $41,760 | Not Implemented |