Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
16
matching recommendationsSIC | 231 | Men's And Boys' Suits, Coats, And Overcoats |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0033 # 01 Y:2009 | 01 | 2009 | USE MINIMUM STEAM OPERATING PRESSURE | $1,091 | $0 | Implemented |
DL0033 # 02 Y:2009 | 02 | 2009 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $5,409 | $9,300 | Implemented |
DL0033 # 03 Y:2009 | 03 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,789 | $16,100 | Implemented |
DL0033 # 04 Y:2009 | 04 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,737 | $10,000 | Implemented |
DL0033 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $580 | $80 | Implemented |
DL0033 # 06 Y:2009 | 06 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $3,596 | $12,500 | Not Implemented |
DL0033 # 07 Y:2009 | 07 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $310 | $150 | Implemented |
DL0033 # 08 Y:2009 | 08 | 2009 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $6,433 | $26,980 | Implemented |
LE0153 # 01 Y:2003 | 01 | 2003 | ADD AREA LIGHTING SWITCHES | $3,181 | $1,375 | Not Implemented |
LE0153 # 02 Y:2003 | 02 | 2003 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $4,007 | $4,000 | Not Implemented |
LE0153 # 03 Y:2003 | 03 | 2003 | INSULATE BARE EQUIPMENT | $19,979 | $7,500 | Not Implemented |
LE0153 # 04 Y:2003 | 04 | 2003 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $2,432 | $1,500 | Not Implemented |
LE0153 # 05 Y:2003 | 05 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,189 | $750 | Implemented |
LE0153 # 06 Y:2003 | 06 | 2003 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $4,948 | $1,000 | Implemented |
LE0153 # 07 Y:2003 | 07 | 2003 | INSTALL OCCUPANCY SENSORS | $766 | $75 | Implemented |
LE0153 # 08 Y:2003 | 08 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,976 | $877 | Implemented |