Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
36
matching recommendationsSIC | 231 | Men's And Boys' Suits, Coats, And Overcoats |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0572 # 01 Y:1996 | 01 | 1996 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $149,480 | $150,000 | Not Implemented |
TN0572 # 02 Y:1996 | 02 | 1996 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $13,909 | $15,800 | Implemented |
TN0572 # 03 Y:1996 | 03 | 1996 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,987 | $0 | Implemented |
TN0572 # 04 Y:1996 | 04 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,413 | $0 | Not Implemented |
TN0572 # 05 Y:1996 | 05 | 1996 | INSULATE BARE EQUIPMENT | $1,469 | $1,548 | Implemented |
TN0572 # 06 Y:1996 | 06 | 1996 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $454 | $472 | Implemented |
TN0572 # 07 Y:1996 | 07 | 1996 | INSULATE BARE EQUIPMENT | $337 | $286 | Implemented |
TN0418 # 01 Y:1991 | 01 | 1991 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $10,212 | $1,840 | Implemented |
TN0418 # 12 Y:1991 | 12 | 1991 | INSTALL SET-BACK TIMERS | $200 | $410 | Implemented |
TN0418 # 02 Y:1991 | 02 | 1991 | KEEP LAMPS AND REFLECTORS CLEAN | $8,262 | $0 | Implemented |
TN0418 # 03 Y:1991 | 03 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $710 | $628 | Implemented |
TN0418 # 04 Y:1991 | 04 | 1991 | CLOSE OFF UNNEEDED STEAM LINES | $762 | $0 | Implemented |
TN0418 # 05 Y:1991 | 05 | 1991 | INSTALL SET-BACK TIMERS | $3,562 | $0 | Implemented |
TN0418 # 06 Y:1991 | 06 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $399 | $0 | Implemented |
TN0418 # 07 Y:1991 | 07 | 1991 | USE MINIMUM STEAM OPERATING PRESSURE | $319 | $0 | Implemented |
TN0418 # 08 Y:1991 | 08 | 1991 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,254 | $0 | Implemented |
TN0418 # 09 Y:1991 | 09 | 1991 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $122 | $25 | Implemented |
TN0418 # 10 Y:1991 | 10 | 1991 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $69 | $0 | Implemented |
TN0418 # 11 Y:1991 | 11 | 1991 | INSULATE BARE EQUIPMENT | $62 | $146 | Implemented |
TN0415 # 06 Y:1990 | 06 | 1990 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $258 | $150 | Implemented |
TN0415 # 05 Y:1990 | 05 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,976 | $0 | Implemented |
TN0415 # 04 Y:1990 | 04 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,850 | $1,500 | Not Implemented |
TN0415 # 03 Y:1990 | 03 | 1990 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,507 | $2,445 | Implemented |
TN0415 # 02 Y:1990 | 02 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,195 | $9,000 | Implemented |
TN0415 # 01 Y:1990 | 01 | 1990 | KEEP LAMPS AND REFLECTORS CLEAN | $35,067 | $44,200 | Implemented |