Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
772
matching recommendationsSIC | 232 | Men's And Boys' Furnishings, Work Clothing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0591 # 03 Y:1996 | 03 | 1996 | INCREASE AMOUNT OF CONDENSATE RETURNED | $21,690 | $11,410 | Not Implemented |
GT0591 # 04 Y:1996 | 04 | 1996 | COVER OPEN TANKS | $2,320 | $1,200 | Implemented |
GT0591 # 05 Y:1996 | 05 | 1996 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $5,120 | $200 | Implemented |
GT0591 # 06 Y:1996 | 06 | 1996 | REPAIR OR REPLACE STEAM TRAPS | $7,900 | $800 | Not Implemented |
GT0591 # 07 Y:1996 | 07 | 1996 | METER WASTE WATER | $17,050 | $1,800 | Not Implemented |
GT0591 # 08 Y:1996 | 08 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,900 | $50,750 | Not Implemented |
GT0591 # 09 Y:1996 | 09 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,520 | $1,020 | Not Implemented |
GT0591 # 10 Y:1996 | 10 | 1996 | OPTIMIZE PLANT POWER FACTOR | $8,510 | $13,400 | Not Implemented |
AR0094 # 01 Y:1996 | 01 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $602 | $412 | Not Implemented |
AR0094 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,701 | $1,445 | Not Implemented |
AR0094 # 03 Y:1996 | 03 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,020 | $1,000 | Not Implemented |
AR0094 # 04 Y:1996 | 04 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $521 | $200 | Not Implemented |
AR0094 # 05 Y:1996 | 05 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $882 | $1,520 | Not Implemented |
AR0094 # 06 Y:1996 | 06 | 1996 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $756 | $756 | Not Implemented |
AR0094 # 07 Y:1996 | 07 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $44,850 | $8,000 | Not Implemented |
MS0056 # 01 Y:1996 | 01 | 1996 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $2,295 | $3,000 | Implemented |
MS0056 # 02 Y:1996 | 02 | 1996 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $9,787 | $24,862 | Implemented |
MS0056 # 03 Y:1996 | 03 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $887 | $1,000 | Implemented |
MS0056 # 04 Y:1996 | 04 | 1996 | USE RE-USABLE FILTERS | $1,090 | $900 | Not Implemented |
MS0056 # 05 Y:1996 | 05 | 1996 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $2,940 | $0 | Not Implemented |
GT0583 # 01 Y:1996 | 01 | 1996 | COMBINE UTILITY METERS | $9,200 | $18,400 | Implemented |
GT0583 # 02 Y:1996 | 02 | 1996 | AIR CONDITION ONLY SPACE NECESSARY | $17,420 | $15,000 | Implemented |
GT0583 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $90 | $3,900 | Implemented |
GT0583 # 04 Y:1996 | 04 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $200 | $360 | Not Implemented |
GT0583 # 05 Y:1996 | 05 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $390 | $500 | Implemented |