Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
772
matching recommendationsSIC | 232 | Men's And Boys' Furnishings, Work Clothing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0261 # 03 Y:1985 | 03 | 1985 | INSTALL SET-BACK TIMERS | $628 | $0 | Implemented |
TN0261 # 04 Y:1985 | 04 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $554 | $300 | Implemented |
TN0261 # 05 Y:1985 | 05 | 1985 | INSTALL / REPAIR INSULATION ON STEAM LINES | $129 | $100 | Implemented |
TN0261 # 06 Y:1985 | 06 | 1985 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $111 | $35 | Implemented |
TN0261 # 07 Y:1985 | 07 | 1985 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $92 | $0 | Implemented |
TN0260 # 01 Y:1985 | 01 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,755 | $0 | Implemented |
TN0260 # 02 Y:1985 | 02 | 1985 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,155 | $300 | Not Implemented |
TN0260 # 03 Y:1985 | 03 | 1985 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $696 | $200 | Not Implemented |
TN0260 # 04 Y:1985 | 04 | 1985 | INSULATE BARE EQUIPMENT | $533 | $300 | Not Implemented |
AT0008 # 01 Y:1985 | 01 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,812 | $150 | Implemented |
AT0008 # 02 Y:1985 | 02 | 1985 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $128 | $222 | Not Implemented |
AT0008 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $251 | $173 | Not Implemented |
AT0008 # 04 Y:1985 | 04 | 1985 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $2,560 | $1,050 | Not Implemented |
UD0154 # 01 Y:1985 | 01 | 1985 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $187 | $20 | Implemented |
UD0154 # 02 Y:1985 | 02 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $593 | $54 | Implemented |
UD0154 # 03 Y:1985 | 03 | 1985 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $803 | $0 | Not Implemented |
UD0154 # 04 Y:1985 | 04 | 1985 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $3,569 | $3,160 | Not Implemented |
TN0238 # 01 Y:1984 | 01 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,856 | $0 | Not Implemented |
TN0238 # 02 Y:1984 | 02 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,292 | $794 | Implemented |
TN0238 # 03 Y:1984 | 03 | 1984 | REPAIR AND ELIMINATE STEAM LEAKS | $956 | $140 | Implemented |
TN0238 # 04 Y:1984 | 04 | 1984 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $1,287 | $0 | Implemented |
TN0238 # 05 Y:1984 | 05 | 1984 | USE MINIMUM STEAM OPERATING PRESSURE | $257 | $0 | Implemented |
TN0238 # 06 Y:1984 | 06 | 1984 | INSULATE BARE EQUIPMENT | $510 | $253 | Not Implemented |
TN0238 # 07 Y:1984 | 07 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $707 | $0 | Not Implemented |
TN0238 # 08 Y:1984 | 08 | 1984 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $1,795 | $480 | Implemented |