IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

106

matching recommendations
Reset
SIC 2321 Men's and Boys' Shirts, Except Work Shirts
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AT0103 # 03 Y:1988 03 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $448 $200 Implemented
AT0103 # 04 Y:1988 04 1988 IMPROVE LUBRICATION PRACTICES $369 $0 Implemented
AT0103 # 05 Y:1988 05 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $148 $0 Implemented
AT0103 # 06 Y:1988 06 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $176 $0 Implemented
AT0103 # 07 Y:1988 07 1988 KEEP BOILER TUBES CLEAN $397 $400 Implemented
AT0103 # 08 Y:1988 08 1988 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $125 $300 Implemented
AT0094 # 01 Y:1988 01 1988 ISOLATE HOT OR COLD EQUIPMENT $1,869 $0 Implemented
AT0094 # 02 Y:1988 02 1988 KEEP LAMPS AND REFLECTORS CLEAN $2,253 $4,245 Implemented
AT0094 # 03 Y:1988 03 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $183 $0 Not Implemented
AT0094 # 04 Y:1988 04 1988 IMPROVE LUBRICATION PRACTICES $457 $0 Not Implemented
LT0070 # 01 Y:1986 01 1986 INSTALL TIMERS AND/OR THERMOSTATS $13,897 $1,300 Implemented
LT0070 # 02 Y:1986 02 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $486 $145 Not Implemented
LT0070 # 03 Y:1986 03 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $332 $65 Not Implemented
GT0275 # 01 Y:1985 01 1985 INSTALL SET-BACK TIMERS $1,780 $0 Implemented
GT0275 # 02 Y:1985 02 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,112 $840 Implemented
GT0275 # 03 Y:1985 03 1985 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $197 $217 Implemented
GT0275 # 04 Y:1985 04 1985 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $13,210 $45,000 Not Implemented
TN0261 # 01 Y:1985 01 1985 INSTALL TIMERS AND/OR THERMOSTATS $1,664 $1,400 Not Implemented
TN0261 # 02 Y:1985 02 1985 REPAIR AND ELIMINATE STEAM LEAKS $1,200 $75 Implemented
TN0261 # 03 Y:1985 03 1985 INSTALL SET-BACK TIMERS $628 $0 Implemented
TN0261 # 04 Y:1985 04 1985 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $554 $300 Implemented
TN0261 # 05 Y:1985 05 1985 INSTALL / REPAIR INSULATION ON STEAM LINES $129 $100 Implemented
TN0261 # 06 Y:1985 06 1985 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $111 $35 Implemented
TN0261 # 07 Y:1985 07 1985 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $92 $0 Implemented
OK0092 # 01 Y:1983 01 1983 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $3,355 $9,600 Not Implemented