Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
96
matching recommendationsSIC | 2329 | Men's and Boys' Clothing, Not Elsewhere Classified |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0101 # 06 Y:1998 | 06 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $7,360 | $420 | Implemented |
MS0101 # 03 Y:1998 | 03 | 1998 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,386 | $1,000 | Implemented |
MS0101 # 04 Y:1998 | 04 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,750 | $0 | Implemented |
MS0056 # 01 Y:1996 | 01 | 1996 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $2,295 | $3,000 | Implemented |
MS0056 # 02 Y:1996 | 02 | 1996 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $9,787 | $24,862 | Implemented |
MS0056 # 03 Y:1996 | 03 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $887 | $1,000 | Implemented |
AR0073 # 01 Y:1995 | 01 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,271 | $3,600 | Implemented |
AR0073 # 03 Y:1995 | 03 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,124 | $300 | Implemented |
AR0073 # 04 Y:1995 | 04 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,644 | $150 | Implemented |
AR0073 # 05 Y:1995 | 05 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,229 | $5,120 | Implemented |
AR0073 # 08 Y:1995 | 08 | 1995 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $515 | $1,000 | Implemented |
AR0073 # 09 Y:1995 | 09 | 1995 | MINIMIZE WATER USAGE | $175 | $200 | Implemented |
NC0042 # 01 Y:1994 | 01 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $7,878 | $5,000 | Implemented |
NC0042 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,578 | $16,665 | Implemented |
GT0470 # 02 Y:1992 | 02 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $180 | $215 | Implemented |
GT0470 # 03 Y:1992 | 03 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $117 | $1,780 | Implemented |
GT0470 # 04 Y:1992 | 04 | 1992 | OVERLAP CUSTODIAL SERVICES WITH NORMAL DAY HOURS | $3,837 | $0 | Implemented |
GT0470 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,463 | $20,590 | Implemented |
GT0470 # 05 Y:1992 | 05 | 1992 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $950 | $460 | Implemented |
GT0470 # 06 Y:1992 | 06 | 1992 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,908 | $4,450 | Implemented |
GT0470 # 07 Y:1992 | 07 | 1992 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $4,526 | $3,940 | Implemented |
IA0027 # 02 Y:1992 | 02 | 1992 | INSTALL / REPAIR INSULATION ON STEAM LINES | $533 | $361 | Implemented |
IA0027 # 04 Y:1992 | 04 | 1992 | INSTALL SET-BACK TIMERS | $2,643 | $3,441 | Implemented |
IA0027 # 05 Y:1992 | 05 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $274 | $172 | Implemented |
IA0027 # 07 Y:1992 | 07 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $423 | $600 | Implemented |